Starter
I
WARNING
: Review the "Safety Bulletin" and diagrams on pages
13-15 prior to installing the starter system.
1. Use a voltmeter to find the wire that shows +12 volts while the ignition
key is in the "CRANK" position
only
and 0 volts while the key is in the
"OFF," "ON" and "RUN" positions.
2. Cut the wire in half. Test by trying to crank the starter with the ignition
key. If it will not crank, you have the correct wire.
3. Connect the
YELLOW
wire to the ignition switch side of the starter wire.
4. Connect the
VIOLET
wire to the starter solenoid side of the starter wire.
Door Lock/Unlock
I
CAUTION
: Be sure to verify the type of door lock system you are
working with. Some types of door lock systems require optional
relays, for example, reverse polarity type door locks. Refer to the
diagrams on pages 15-17.
The system can operate both negative and positive door locks. When the
alarm is remotely armed, the
BLUE/WHITE
wire provides a negative output.
At the same time, the
GREEN/WHITE
wire provides a 300 mA positive output.
When the alarm is remotely disarmed, the
GREEN/WHITE
wire provides a
negative output. At the same time the
BLUE/WHITE
wire provides a 300 mA
positive output.
12
AviStart 6001 Installation Manual - 0999
Summary of Contents for AviStart 6001
Page 1: ...AviStart 6001 Installation Manual 0999 ...
Page 5: ...3 AviStart 6001 Installation Manual 0999 Main Wiring Diagram ...
Page 6: ...4 AviStart 6001 Installation Manual 0999 Satellite Relay Module Diagram ...
Page 18: ...16 AviStart 6001 Installation Manual 0999 ...
Page 19: ...17 AviStart 6001 Installation Manual 0999 ...