Old Programming Mode
The old programming menu is still available on the Memcom
+
unit. To access this mode of programming, from the idle screen, simply enter the
old programming passcode (default- *1234#). The old method of programming can also be used remotely, by dialing the phone number of the
Memcom, and following the same instructions.
Old Menu Structure
Quick Start Guide to programming…
Programming options for the type of Memcom
+
Alarm / Software Calls
*11 1st (Alarm Tel Number) # Program 1st Alarm Number
*15 5th (telephone alarm number) **1# Program Technical Alarm Number
*16 6th (telephone alarm number) **1# Program EN81-28 Background Test Call Number
Suffix
Protocol
#
Guided message for call centre
**0#
No guided message for call centre.
**1#
Memco Protocol - compatible with Avire Hub, Memcom ETR Software or
GlobalNet
**3#
P100 Protocol - Recommended for Avire Hub.
**4#
Alternative to # for use when Memcom is configured for Hotline operation.
**6#
Contact ID Protocol
*23 Volume TOC 5, COP 0 Adjustable between 0-9 (0 = minimum setting)
*41 Location message: 1: Play Location 2: Record Location Message
*26 Hardware
Defaults: 12 TOC Version 8 COP Version
1 = EN81-28 operating mode opts
2 = Service Input = Tech.2
4 = Disable internal microphone
8 = Consecutive dial mode
16 = Enable Memcom
+
GSM module
64 = Alarm Input N/C
128 = Czech, Greek, Italian and Singaporean
dial tone cadences for use with multiple
Memcom
+
only
256 = Service Input as Alarm Activation
512 = COP Accessory attached (450 200 & 450
250).
Any combination can be programmed. Enter
sum of the numbers of the options required.
*27 Hardware Monitoring
Default: 39
1 = PSU monitoring
2 = Battery supply
4 = Phone line, (Do not use if
connected to a hotline)
8 = GSM Low signal
16 = GSM No signal
32 = Microphone/speaker test
64 = Power Logging
Any combination can be
programmed. Enter sum of the
numbers of the options required.
Exiting Programming
Press # to return to programming home screen, then enter one of the following exit
codes...
*01# Exit programming without making an alarm call
*03# Exit programming and call Alarm number 6 EN81-28
*021# Exit programming and call Alarm number 1 only
*035# Exit programming and call Alarm Number 5 Technical Alarm
*94
Total Count
*93
Due in Count
*92
Service Count
*91
Model/HW/SW
*90
GSM Signal
*84
EOA
*83
Not in Use
*82
Relay o/ride
*81
GSM SIM Pin
*61
Language
*52
Service Count
*51
Serv. Interval
*43
Guidance
*42
Reassurance
*41
Location
*40
Relay Mode
*39
PBX Freq.
*38
Hangup delay
*37
Test Call on
*36
Tech 2 Delay
*35
Tech 1 Delay
*34
TopOfCar Dly
*33
MPS Delay
*32
Answer Delay
*31
In-Car Delay
*29
GMT Offset
*28
Network ID
*27
Hardware Mon.
*26
Hardware Opts
*25
Set Date
*24
Set Time
*23
Speaker Vol.
*22
Password
*21
ID Code
*17
Dial Attempts
*16
Background
*15
Tech Alm
*14
Alarm No4
*13
Alarm No3
*12
Alarm No2
*11
Alarm No1
M
emc
om IG V
03 (ML) \EP 12/
08/20
21
Memco
is a brand of Avire
Avire Trading Ltd
Unit 1, The Switchback
Gardner Road
Maidenhead
Berkshire SL6 7RJ, UK
T:
01628 540100
E:
W:
www.avire-global.com
If you require any further assistance when programming the Memcom
+
unit, please call our Technical Service Team on
01628 540160.