Specifications
System
Avigilon Control Center Software
Enterprise, Standard and Core
Operating System
Windows Embedded Standard 7 software
Hard Disk Drive Configuration
Near-line SAS, hot swappable, RAID 5
Mechanical
Dimensions (LxWxH)
674.7 mm x 482.4 mm x 42.95 mm; 26.56” x 18.99” x 1.69”
Weight
13.8 kg (30.42 lb)
Form Factor
1U rack
Electrical
Power Input
100 to 240 V AC, 50/60 Hz, autoranging
Power Consumption
350 W (1194.2 BTU/hr)
Power Supply
Single — optional secondary power supply (HD-NVR3-VAL-
2NDPS-NPC)
Environmental
Operating Temperature
10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the
equipment.
Storage Temperature
-40 °C to 65 °C (-40 °F to 149 °F)
Operating Humidity
10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew
point.
Storage Humidity
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere
must be non-condensing at all times.
Operating Vibration
0.26 Grms at 5 Hz to 350 Hz
Storage Vibration
1.88 Grms at 10 Hz to 500 Hz for 15 min
Operating Shock
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes of 40 G for up to 2.3 ms.
Storage Shock
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system) of
71 G for up to 2 ms.
Operating Altitutde
3,048 m (10,000 ft).
Storage Altitutde
12,000 m (39,370 ft)
Certifications
Safety
EN 60950-1:2006 / A11:2009 / A1:2010 / A12:2011 / A2:2013
UL/CSA/IEC 60950-1, 2 Ed + Am 1: 2009 + Am 2: 2013
EN 62311:2008
Power Efficiency
80 PLUS Titanium
Specifications