Power On
Follow the steps below to power on and verify the installation:
Note
: Once connected, the card readers may beep – this will go away once the ACM Embedded Controller has
been configured.
1. Connect the High Voltage AC input to the FPO power supply.
CAUTION —
Take necessary precautions when handling high voltage wiring. This step should be
completed by a qualified electrician.
NOTE:
On the FPO250 (on the top above) and FPO75 (below the FPO250) PSUs the AC light (green - see 1
above) should be on and all warning lights (see 2 above) should be off.
2. Connect the battery set(s), if applicable. See the FPO Quick Start Manual (page 1 – Battery Terminal
Connection) for more detail. Further information is available at:
http://lifesafetypower.com/docs/im_
.
NOTE:
If using battery backup then a separate enclosure is required for the batteries due to space
limitations in this enclosure.
CAUTION —
Observe battery polarity or damage to the system will occur.
3. Connect the ACM Embedded Controller J1 Ethernet port to a laptop or desktop computer (preferably
offline as if you are networked the network may interfere with the IP address).
CAUTION —
Do not connect the ACM Embedded Controller to a PoE port.
25