background image

WIFI-CONNECTED
SMOKE DETECTOR

HomeSmoke

EN

Ref.127065

www.avidsen.com

V1

TECHNICAL

SUPPORT

1.5 V AA X2

90dB

WIRELESS

EASY

TO INSTALL

WARRANTY

YEARS

Works

with the app

avidsen Home

Summary of Contents for 127065

Page 1: ...WIFI CONNECTED SMOKE DETECTOR HomeSmoke EN Ref 127065 www avidsen com V1 TECHNICAL SUPPORT 1 5 V AA X2 90dB WIRELESS EASY TO INSTALL WARRANTY YEARS Works with the app avidsen Home ...

Page 2: ...DESCRIPTION 1 KIT CONTENTS 06 2 SMART SMOKE DETECTOR 06 3 INSTALLATION AREA 07 C INSTALLATION 1 INSTALLING THE DETECTOR ON THE WALL OR CEILING 08 2 REPLACING THE BATTERIES 08 D BEGINNING OPERATION 1 INDICATOR LIGHT 09 2 CONNECTION 09 2 1 Installing the mobile application and creating an account 09 2 2 Connecting the smoke detector 10 WIFI CONNECTED SMOKE DETECTOR ...

Page 3: ...EN 3 E USE 1 USE VIA THE APP 13 F TECHNICAL AND LEGAL INFORMATION 1 TECHNICAL CHARACTERISTICS 13 2 WARRANTY 14 3 HELP AND ADVICE 14 4 EU DECLARATION OF CONFORMITY 14 ...

Page 4: ...t method Test the smoke detector once a week to make sure it is working properly 2 Do not remove or disconnect the battery This would remove your protection 3 Observe and follow all electrical instructions in the building code for installation 4 This smoke detector is designed for indoor use only In buildings each apartment must have its own smoke detector 5 Install a smoke detector in each room a...

Page 5: ...ion of the smoke detector 4 MAINTENANCE AND CLEANING The outer case can be cleaned periodically Do not use abrasive substances substances containing alcohol thinners or other flammable substances Do not spray any products directly onto the unit 5 RECYCLING This logo denotes that devices no longer in use should not be disposed of as household waste They are likely to contain hazardous substances wh...

Page 6: ...TS 1 x1 2 SMART SMOKE DETECTOR WIFI CONNECTED SMOKE DETECTOR 1 WIFI smoke detector 2 AA battery LR06 x2 3 Self adhesive double sided tape mount 4 Screws 2 x2 3 x1 4 x2 1 Button 2 Warning light 3 Siren 4 Air inlet for smoke detection 3 4 2 1 ...

Page 7: ...y X Attic X Basement X Garage X Boiler room X 500 m m 1000 m m 20 500 mm 1000 mm 500 m m 1000 m m 20 500 mm 1000 mm 500 m m 1000 m m 500 mm 1000 mm CEILING BEST HERE NEVER HERE DO NOT INSTALL DO NOT INSTALL VAULTED CEILING ATTIC CEILING ANYWHERE IN THIS AREA ANYW HERE IN THIS AREA NO T IN THIS AREA NOT IN THIS AREA DEAD SPACE DEAD SPACE DEAD SPACE 50 cm MINIMUM ...

Page 8: ...EN 8 C INSTALLATION 1 INSTALLING THE DETECTOR ON THE WALL OR CEILING 2 REPLACING THE BATTERIES WIFI CONNECTED SMOKE DETECTOR ...

Page 9: ...nds The alarm sounds Release the test button Mute function If the alarm sounds in error while cooking it can be paused for 10 minutes by pressing the test button The LED indicator flashes once every 8 seconds Locate the alarm source before using the mute function to make sure it is not a life threatening situation 2 CONNECTION 2 1 INSTALLING THE MOBILE APP AND CREATING AN ACCOUNT This product only...

Page 10: ...ion set a password between 6 and 20 characters long with letters and numbers only then press Terminé Finished 2 2 CONNECTING THE SMOKE DETECTOR Press the button 3 times in less than 2 seconds to put the product in pairing mode The indicator light will start flashing until the pairing procedure is completed If it doesn t follow the reset procedure on your phone To start pairing press AJOUTER ADD Ma...

Page 11: ...horisation request message appears you need to accept it for your Android or iOS device to receive your WiFi IMPORTANT This device is compatible with 2 4 GHz WPA WPA2 networks Not compatible with 5 GHz WiFi or with WEP encryption Please check the WiFi settings of your router or contact your Internet service provider if you experience connection difficulties If this message appears Click on Changem...

Page 12: ...I CONNECTED SMOKE DETECTOR Your smoke detector is now operational and will appear in your app You can now control your Avidsen sensor from your smartphone You can rename it by clicking on the small pencil to the right of the device name ...

Page 13: ...ance of 1 metre Smoke detection sensitivity 0 108 0 141dB m Temperature detection sensitivity 54 70 C Noise emission when smoke is detected BI 0 5s pause 0 5s BI 0 5s pause 0 5s BI 0 5s pause 1 5s the red LED flashes this sequence is repeated noise emission when temperature is detected BI 0 2s pause 0 1s the red LED flashes this sequence is repeated Max EIRP 20 dB m Operating T 0 C 40 C Storage T ...

Page 14: ...he problem is caused by the product itself the technician will give you an RMA number so that you can return the unit to the shop Without this RMA number the shop may refuse to exchange your product Need advice for the installation or start up of your product Contact our after sales service team technicians 0 35 min 0 892 701 369 Monday to Friday 9am to 12pm and 2pm to 6pm Avidsen undertakes to ke...

Page 15: ......

Page 16: ...Avidsen 19 avenue Marcel Dassault ZAC des Deux Lions 37200 Tours France ...