![Avidsen 127062 Manual Download Page 6](http://html.mh-extra.com/html/avidsen/127062/127062_manual_3031508006.webp)
EN
6
C - INSTALLATION
Before the device is permanently installed, make
sure it is within WIFI range of your router. If it is
installed outside WIFI range, you should install a
WIFI repeater to boost the signal.
1 - WIRING AND MOUNTING
Wiring diagram based on the type of installation.
Refer to the manual for your heating equipment.
N
N
L
2
3
1
4
5
6
L
NO NC COM
L
Electric valve
/pump
N
N
L
2
3
1
4
5
6
L
NO NC COM
L
Hot wire
N
N
L
2
3
1
4
5
6
L
NO NC COM
L
Boiler
N
N
L
2
3
1
4
5
6
L
NO NC COM
L
Expansion
valve
6
5
4
3
2
1
Caution: before beginning this step, make sure the
power supply has been cut. When in doubt, please
contact a professional to complete the installation.
1. Open the thermostat.
2. Attach the power supply to the wall (use screws
suitable to the support).
3. Open the central cover and connect (refer to the
diagram above depending on your installation).
4. Close the cover and plug the screen into the
power supply.
2 - SETTINGS
2.1 - SETTING THE DATE AND TIME
1. Press
PRG
once until the date symbol flashes,
press the
PRG
or
PRG
buttons to adjust the current
day.
2. Press
PRG
once until the month