background image

 

 

 

    

PROCEDURE

    

 

Procedure P/N

 

Title

PROKEYS SONO 61/88 

Revision:

  

 

Page  1 of 6 

 

UNCONTROLLED DOCUMENT when printed or copied 

Date Printed:  3/24/2010 

 

Form: 0150-30027-01 Rev C 

 

 
1.0

 

Scope 

This procedure defines the method required to test the ProKeys Sono 61 
and 88 digital keyboards. 

 

9900-53102-10  PROKEYS SONO 88 INCL PRO TOOLS ES, NO 
PWR

 

 

9900-52551-10  PROKEYS SONO 88, NO POWER

 

 

9900-53104-10  PROKEYS SONO 61 INCL PRO TOOLS ES, NO 
PWR

 

 

9900-52550-10  PROKEYS SONO 61, NO POWER

 

 

2.0

 

Reference Documents 

2.1

 

M-Audio Dealer Check in sheet 

2.2

 

M-Audio Scrap log 

2.3

 

M-Audio RTV Log 

 

3.0

 

Equipment 
3.1

 

Audio Source (DVD Player)

 

3.2

 

RCA male to RCA male cable x2

 

3.3

 

RCA male to ¼” cable

 

3.4

 

¼” TRS to ¼” TRS cable x2

 

Summary of Contents for PROKEYS SONO 61

Page 1: ...no 61 and 88 digital keyboards 9900 53102 10 PROKEYS SONO 88 INCL PRO TOOLS ES NO PWR 9900 52551 10 PROKEYS SONO 88 NO POWER 9900 53104 10 PROKEYS SONO 61 INCL PRO TOOLS ES NO PWR 9900 52550 10 PROKEYS SONO 61 NO POWER 2 0 Reference Documents 2 1 M Audio Dealer Check in sheet 2 2 M Audio Scrap log 2 3 M Audio RTV Log 3 0 Equipment 3 1 Audio Source DVD Player 3 2 RCA male to RCA male cable x2 3 3 R...

Page 2: ...ds to be in the like new state All knobs turned to the left all faders down and the product turned OFF 4 2 The computer is ON 4 3 Connect the USB cable from the computer to the ProKeys Sono unit 4 4 Connect the power cable to the ProKeys Sono unit 4 5 Connect speakers left and right to the Output R and L Mono ports on the back of the unit 4 6 RESET the ProKeys Sono during power up by pressing and ...

Page 3: ...ces 4 9 In the MIDI Devices window in the MIDI Input field select 1 ProKeys Sono 61 or 88 4 10 In the MIDI Output field select 1 Microsoft GS Wavetable SW Synth and 2 ProKeys Sono 61 or 88 MIDI Out 4 11 Check the Port Mapping field to see that both choices from the MIDI Output field are displayed 4 12 Click OK 4 13 TEST KEYBOARD FUNCTIONS 4 13 1 Push the VOLUME up to MAX Check for a response in MI...

Page 4: ...OX 4 13 5 Press the Octave Data buttons while tapping a key on the keyboard Test for sound modulation 4 13 6 Press the Edit Mode button blue light should come on 4 13 7 Individually press each button in the Voice Select section and test keys on the keyboard for sound check and a response in MIDI OX 4 13 8 Press the Grand Piano button in Voice Select 4 13 9 Individually press each button in the Voi...

Page 5: ...he back of the unit 4 13 16 Press the pedal and check for a response in MIDI OX 4 13 17 Disconnect SP 2 Sustain Pedal and headphones 4 14 TEST AUDIO CONTROLS 4 14 1 Connect audio source to Aux Input R on the back of the ProKeys Sono 4 14 2 Test the Direct Monitor knob for sound from the right speaker 4 14 3 Depress the Mono button sound should come from both speakers 4 14 4 Release the Mono button...

Page 6: ...he back of the ProKeys Sono 4 14 12 Test the Mic Gain knob for sound volume control 4 14 13 Disconnect audio source and microphone 4 15 TEST MIDI 4 15 1 Connect the ProKeys Sono MIDI OUT to the In port on the MIDI sound module MidiSport 4 15 2 Connect speakers to the MIDI sound module 4 15 3 Press keys on the ProKeys Sono keyboard to test for sound 4 16 TEST COMPLETION 4 16 1 Turn the ProKeys Sono...