![Avid Technology MV3000 DELTA Technical Manual Download Page 148](http://html1.mh-extra.com/html/avid-technology/mv3000-delta/mv3000-delta_technical-manual_3031206148.webp)
Maintenance
T1689 Technical Manual Rev 07
SYSTEM DIAGNOSTICS
MV3000 Air Cooled DELTA
Page 148
8.7
SYSTEM DIAGNOSTICS
8.7.1
Controller Diagnostics
The MV3000e Controller provides diagnostic information which can be accessed by use of the optional Drive
Data Manager
(Keypad). The drive conditions for which diagnostic information is available are:
•
drive status;
•
warning of a problem;
•
fault condition;
•
trips.
The controller includes a group of LEDs (Light Emitting Diodes) shown in Figure 8–1 to provide an indication of
the four statuses listed above. All of the diagnostic information, and some of the helpful hints for fault
diagnosis, are detailed in the MV3000e Getting Started Manuals T1676 or T2002 (for AEM systems).
Figure 8–1. – MV3000e Controller LED Functions
All diagnostic information is detailed within the following documents:
a)
MV3000e Software Technical Manual T1679;
b)
T1676 Getting Started Manual for MV3000e AC-Fed Drives;
c)
T2002 Getting Started Manual for MV3000e Active Energy Management Drives
8.7.2
DELTA Transistor Module Diagnostics
The PCB on the DELTA transistor module includes a group of six LEDs that display the operational status of the
module. The LED functions are shown in Figure 8–2.
Figure 8–2. – DELTA Transistor Module LED Functions
Tripped
Warning
Running
Ready
D5
D79
D80
D18
D39
D54
RS485
Transmit
RS485
Receive
+ 5 V OK
Running
Fan 1 OK
+ 15 V OK
Healthy
Fan 2 OK
DELTA Interface PCB
20X4381 / 20X4384