A
Specifications
242
Connector Pinouts and Connections
The following connectors are listed in this section:
•
RS-422 Serial Control Mechanism Connections
•
RS-422 Serial Remote RJ45 Connector Specifications
•
Ethernet Connector Specifications
•
Expansion Port Connector Specifications
•
LTC Timecode Connector Specifications
•
USB 2 Connector Specifications
w
In order to ensure emission compliance, all cables attached to connectors on the
AirSpeed Multi Stream chassis must be fully shielded and properly grounded to the
connector shell where possible.
RS-422 Serial Control Mechanism Connections
Avid uses the industry standard guidelines for the RS-422 connection between capture and
playout servers and the control mechanism. The maximum cable length is 1200 m (4000 ft)
based on Baud Rate and a other variables (for example the cable type and electrical noise in
the environment).
RS-422 Serial Control Cables
Baud Rate
Maximum Cable Length
1200
1200 m (4000 ft)
4800
1200 m (4000 ft)
9600
1200 m (4000 ft)
38400
1200 m (4000 ft)
115200
1000 m (3280 ft)