8
[Y] is the input channel of matrix switcher
Example
If you send the “EDIDM2B1.” to the matrix switcher, you will copy the EDID data of output2 to the
input1.
If the second output is connected Sharp LCD, the input 1 is connected IBM PC. It means the Sharp
LCD and IBM PC are directly EDID communication.
6.3 Restore the factory default EDID
When you need to restore the factory default EDID, you can pressing the front panel or sending the
RS232 command.
When the factory-restore is well carried, the RS232 will send out the feedback command: “EDIDMInit”
RS232 command
(ASCII, 9600bps. 8N1)
Feedback Code
The Operation of Front Panel Buttons
EDIDMInit.
EDIDMInit
Press the button”
←
”for 30 seconds, till the LED light up
And then, press ”AV”+””UNDO”
After 8 seconds, the ”
←
” LED will be off.
The front penal operation: