![Avery Weigh-Tronix ZM510 User Instructions Download Page 12](http://html1.mh-extra.com/html/avery-weigh-tronix/zm510/zm510_user-instructions_3030558012.webp)
12
US ZM510 Indicator User Instructions
Introduction
2 Introduction
The ZM510 indicator is a powerful, programmable indicator with a default accumulator
weighing application. The application database can store 200 accumulation channels.
This manual will explain operation of the indicator and the weighing application.
This indicator is suitable for the office, dusty, wet or high pressure and heavy
washdown environments. It comes in IP69K stainless steel desktop and IP66 panel
mount housings. Both have a high contrast, graphic display for text and graphic
messages appropriate to the function of the program.
The ZM510 indicator can support up to four scales for a total of 24 - 350 ohm load cells.
The indicator requires a line voltage of 90 - 264 VAC, 50 or 60 Hz or 12-36VDC. The
standard indicator connectivity includes two USB Host, three serial ports and an
Ethernet port.
Available options include:
l
Analog Output kit
l
Current Loop kit: Current loop and RS485/RS422
l
USB Device kit: Provides USB interface to PC
l
DeviceNet
TM
l
ProfiBus
®
l
Wireless 802.11g
l
Internal 120 VAC relay
l
2nd Scale Input 5VDC Excitation w/o STVS
l
2nd Scale Input 10 VDC Excitation w/STVS
l
External I/O Interface (for existing GSE or 1310 I/O cards)
l
AC input, 4 Inputs (120-240VAC)
l
DC input, 4 inputs(4-30VDC)
l
AC output, 4 relays (20-240VAC, 1 amp max)
l
DC output, 4 relays (3-60VDC, 2 amp max))
The indicator also has three logic level inputs with configurable functions and three
setpoint outputs. See the Specification literature for a full list of specifications.
Panel mount equipment to be powered by a UL Listed I.T.E. power supply: rated 12-
36VDC and marked “LPS, or a UL Listed power supply rated 12-36VDC and marked
“Class 2.”