RD40RF Remote Display User Instructions
13
3.5.3 RD40RF Interface with 1040/2040 Indicators
This section describes the operation of the RD40RF when communicating to the 1040/
2040 AWT indicators. If there are any questions on the operation of the 1040/2040,
please reference the corresponding user manual.
The RD40RF has the same display as the 1040/2040 indicator. This means that if you
see it on one of the displays, the same is shown on the other. We must remember that
the RD40RF is used with many other indicators that have different functionality. So, the
key names may not always match the operation of the key. Below is a list of the keys
on the RD40RF and the functions that will be performed on the 2040 indicator.
ON/OFF
Turn on and off the RD40RF remote only.
RM
This key is used to advance to the next ingredient when in batching
mode or next pen during unloading mode. Press once to advance.
M+
This key is not used with the 2040.
TARE
Use this key to start a manual loading routine.
Press
TARE
once and a 0 Load/Unload routine is started. The display
shows 0. Load the weight of the first ingredient.
When the target is met, press
TARE
again if there are more ingredients
to load.
To view the gross weight during the loading process, press the
G/N
key
and the gross weight is shown.
Press the
G/N
key again to return to the loading routine.
When done with loading, press
RM
to exit to the gross mode.
The TARE key is not used during automatic loading with the 1040/2040.
G/N
The Gross/Net key is used to see the gross weight during the load/
unload routine.
Press the
G/N
key once and the gross weight is shown until you press
the
G/N
key again to return to loading.
When the gross weight is active on the display, the GROSS annunciator
will be on.
HOLD/MENU
Pressing the
HOLD
key will go into hold mode. The hold mode is used
when moving the mixer and you do not want the weight to shift because
of the change in terrain. Press the
HOLD
key again to return to the
weight.
PRINT/SELECT
This key is used to switch between multiple indicators when SPT-PT is in
use.
ZERO/CLEAR
Pressing the
ZERO/CLEAR
will zero the weight off the indicator when in
gross mode. In automatic loading mode or making a 1040/2040 recipe,
the
ZERO/CLEAR
will not function.