![Avery Weigh-Tronix 7820-50 User Instructions Download Page 25](http://html1.mh-extra.com/html/avery-weigh-tronix/7820-50/7820-50_user-instructions_3030597025.webp)
7800 Family User Instructions
25
5.8
13.
Press the
ZERO
key to scroll through the choices. When the choice you want
is displayed, press the
TEST
key …
Your choice is accepted and the display shows
PRTOUT
.
*Default factory setting
Where:<LF> Represents the line feed character (ØA hex)
W Represents a weight digit character
uu Represents the unit-of-measure characters (lb or kg)
<CR> Represents the carriage return character (ØD hex)
14.
When finished configuring your scale, press the
ZERO
key until
DONE
is
displayed; then press the
TEST
keys, or close Switch 1 to return to the normal
weighing mode.
5.8 Print Modes
The 78XX provides three options for transmitting displayed weight without requiring a
remote device to initiate the request for weight to the scale. These options are
selectable in the CONF setup menu PROT and are as follows:
AUTO-1:
Weight is automatically transmitted after weight is removed from the scale platform.
The last “stable” weight prior to removing the item will be “sent,” as soon as the
displayed weight returns to within five display divisions (i.e. 5d). This option is normally
used in applications where items are added to a box already placed on the scale, but
where only one weight data transaction is to occur. See note below.
Table 5.3 Output Print Formats
Formatted Output Data String
Selection
Display
<LF>
WWW.WW
uu
<CR>
<LF>
LFuuLF*
<LF>
WWW.WW
uu
<CR>
LFuu—
<LF>
WWW.WW
<CR>
<LF>
LF—LF
<LF>
WWW.WW
<CR>
LF——
WWW.WW
uu
<CR>
<LF>
—uuLF
WWW.WW
uu
<CR>
—uu—
WWW.WW
<CR>
<LF>
——LF
WWW.WW
<CR>
———
To avoid potential erroneous weight values from being transmitted, create enough
instantaneous motion on the platform to avoid a recapture of a stable weight that
might occur if the item were removed slowly.