Classification: Avery Dennison – Public
Configuring the Scanner
3-5
Select
To
Supplemental
Redundancy
Sets the number of times a symbol without supplemental information is
decoded. The range is 2 – 20. The default is 7.
Security
Sets how many times to scan the same bar code to determine a
successful read. The range is 1 – 4. The default is 1. Before setting
this security level, you must decide the print quality of the bar codes you
are scanning. The better the quality of the bar code, the lower the
security level needed.
1 - Choose 1 if most of your scans are successful.
2 - Choose 2 when your unsuccessful scans are related to characters 1,
2, 7, and 8.
3 - Choose 3 when your unsuccessful scans are not limited to characters
1, 2, 7, and 8.
4 - Choose 4 if unsuccessful scans still occur at level 2.
Configuring Code 39 Bar Codes
Code 39 is a linear one-dimensional bar code. Use the
Printer Setup Application
to configure
the Code 39 bar code scanner options below.
Select
To
Enabled
Allows the scanner to scan Code 39 bar codes.
Transmit
Check Digit
Tells the scanner to return the check digit with the data when a Code 39
bar code is scanned.
Convert to
Code32
Tells the scanner to convert Code 39 bar codes to Code 32 bar codes.
Verify Check
Digit
Tells the scanner to check the integrity of all Code 39 bar codes that it
scans. Use this option only for Code 39 bar codes with a modulo 43
check digit.
Trioptic 39
Allows the scanner to scan Trioptic Code 39 bar codes. The length is
always 6. Do not enable this bar code and Code 39 Full ASCII at the
same time.
Full ASCI
Allows the scanner to interpret data in a Code 39 bar code as an ASCII
representation. The scanner does not auto discriminate between Code
39 and Code 39 Full ASCII. Do not enable this option and Trioptic Code
39 at the same time.
Code32 Prefix
Allows the scanner to scan Code 32 Prefix bar codes.
Length 1
Length 2
Sets the length(s) for Code 39 bar codes. Lengths include check digits.
For variable length bar codes, set both Length 1 and Length 2 to 0. Use
variable length for Code 39 Full ASCI bar codes.
For a variable range, set Length 1 to the lower limit and Length 2 to the
upper limit.
For
one fixed
length bar codes, set both Length 1 and Length 2 to the
same length. This specifies a single length for valid bar codes.
For
two fixed
length bar codes, set Length 2 to the
shorter
length and
Length 1 as the
longer
length.
The range for Length 1 is 0 to 99. The default is 2.
The range for Length 2 is 0 to 99. The default is 55.