169
8.1 T
YPES
OF
STATUS
MESSAGES
ALS
20X
256
8.1.6
List of error messages
Status Status text
Cause
Action to take
1007
Command incorr.
Unknown interface command at data in-
terface.
Check the command that was sent to
the data interface as necessary.
1272
#!A.. wrong
Number
Error in command "#!A..". The value en-
tered for the parameter is outside of the
permitted range (0 to 31).
Enter a value within the permitted
range.
1276
#!P.. wrong
Number
Error in command "#!P..". The value en-
tered for the parameter is outside of the
permitted range (0 to 31).
Enter a value within the permitted
range.
1285
#-comm. incorr.
Error in a command "#!..". The letter en-
tered is not valid.
Enter a valid letter.
1401
Para value wrong
A not defined parameter value was sent.
The error occurs for example, if a prod-
uct profile was called with a wrong
number (Easy-Plug command #!PC).
Correct the sent parameter values.
3000
RS232 Overrun
RS232 interface receive error
COM1
(Overrun).
Press the
-key to ack-
nowledge.
3001
RS232 Parity
RS232 interface receive error
COM1
(Parity).
Press Online button to acknowledge.
Check setting in labeller's function
menu:
(
INTERFACE PARA
>COM1 PORT
>
Parity
) and on host computer.
3002
RS232 Frame
RS232 interface receive error
COM1
(Frame).
Press Online button to acknowledge.
Check the setting in the labeller’s
function menu: (
INTERFACE PARA
>COM1 PORT
>
Baud rate
and in the
menu
INTERFACE PARA
>COM1 PORT
>
Stop bits
) as well as on the host com-
puter.
3011
Send buffer full
The send buffer is full. This error can oc-
cur when the status of the labeller was
queried several times (#!Xn), but the re-
sponse was not read out.
Ensure that status response is read
out.
5000
Bus device
– Device at I
2
C Bus cannot be contact-
ed.
– In most cases, this message appears
as the first in a series of two or three
messages which narrow down the er-
ror more precisely.
Delete the message by pressing the
-key.
Switch the machine off, wait 30 se-
conds and switch it back on.
If the error message
appears re-
peatedly, call in a servicing tech-
nician.
[196] List of error messages