NETWORK CABLE INSTALLATION 

A 100’ Cat5e non-plenum UTP camera cable is included with your camera. It 

is important to consider how the network cable is attached to the camera. 
•  If passing the cord through a wall or ceiling, drill a 7/8” hole.
•  We recommend using the waterproof cable connector on all installations.
•  For maximum weather and tamper resistance in outdoor installations, 

place the connection between your camera cable and the camera jack 

within a wall or use a junction box available at avertx.com.

•  For outdoor installations, use silicone caulking to seal any holes in the 

wall or ceiling to protect against leaks.

• 

If your installation is in a commercial building, consult local fire codes. 

Plenum rated cable may be required.

WATERPROOF CABLE CONNECTOR

To use the IP66-rated waterproof cable connector: 

You do not need to re-terminate the cable to use the waterproof cable 

connector

.

 

•  Slide all pieces of the waterproof cable connector over the cable plug in this 

order: 
1.  Small plastic ring
2.  Flexible silicone seal ring. You will need to stretch the silicone seal 

over the RJ-45 plug.

3.  Large plastic ring

•  Slide the rubber “O” ring over the camera plug screw and connect the 

camera cable to the plug on the dongle. Screw the large plastic ring into 

the dongle.

• 

Insert the flexible silicone seal into the “crown” section of the large plastic 

ring

•  Screw the small plastic ring into the large plastic ring

CONNECTING TO THE CAMERA 

This camera is plug and play when connected to an AvertX ProConnect 

Recorder. To access this camera without an AvertX recorder, you will need 

to connect the camera to a Power Over Ethernet Switch and install AvertX 

Network Camera Manager Software on a Windows computer.
1.  Download and install the Camera Finder software at www.avertx.com/

downloads/. Select ONVIF Detection, and click Refresh. 

2.  When the camera is found, click “Load” under the web page. The camera 

admin page will load in a browser.  

3.  Login to the camera using the username 

admin

. The first time the camera is 

accessed you will need to set a password. 

4.  AvertX cameras are set to DHCP by default. If a DHCP server is 

not detected after 4 minutes, the camera will default to IP address 

192.168.51.2.

5.  For assistance connecting directly to your camera, please contact AvertX 

support at 855-228-3789 

MICRO SD CARD AND RESET BUTTON

Your camera is equipped with a slot for a microSD card and a Reset button. 

To access these, you must remove the microSD / Reset cover. 
If you have purchased a microSD card to be used for backup, insert the 

formatted card into the slot. Refer to the user manual for compatible cards 

and how to properly format your microSD Card.
The reset button will return the camera to factory default settings. To reset 

your camera, power cycle the camera then push and hold the reset button for 

10 seconds. This has to be performed immediately after the camera has been 

powered on or the reset will fail.

37026AA

Reset button

microSD slot

Contact AvertX Support: 1-855-228-3789 | www.avertx.com

For more information on installing your AvertX camera, download the  

user manual, read FAQs and DIY resources, and view instructional videos  

at www.avertx.com.

FOR FURTHER INSTRUCTIONS:

Reviews: