NETWORK CABLE INSTALLATION
A 100’ Cat5e non-plenum UTP camera cable is included with your camera. It
is important to consider how the network cable is attached to the camera.
• If passing the cord through a wall or ceiling, drill a 7/8” hole.
• We recommend using the waterproof cable connector on all installations.
• For maximum weather and tamper resistance in outdoor installations,
place the connection between your camera cable and the camera jack
within a wall or use a junction box available at avertx.com.
• For outdoor installations, use silicone caulking to seal any holes in the
wall or ceiling to protect against leaks.
•
If your installation is in a commercial building, consult local fire codes.
Plenum rated cable may be required.
WATERPROOF CABLE CONNECTOR
To use the IP66-rated waterproof cable connector:
You do not need to re-terminate the cable to use the waterproof cable
connector
.
• Slide all pieces of the waterproof cable connector over the cable plug in this
order:
1. Small plastic ring
2. Flexible silicone seal ring. You will need to stretch the silicone seal
over the RJ-45 plug.
3. Large plastic ring
• Slide the rubber “O” ring over the camera plug screw and connect the
camera cable to the plug on the dongle. Screw the large plastic ring into
the dongle.
•
Insert the flexible silicone seal into the “crown” section of the large plastic
ring
• Screw the small plastic ring into the large plastic ring
CONNECTING TO THE CAMERA
This camera is plug and play when connected to an AvertX ProConnect
Recorder. To access this camera without an AvertX recorder, you will need
to connect the camera to a Power Over Ethernet Switch and install AvertX
Network Camera Manager Software on a Windows computer.
1. Download and install the Camera Finder software at www.avertx.com/
downloads/. Select ONVIF Detection, and click Refresh.
2. When the camera is found, click “Load” under the web page. The camera
admin page will load in a browser.
3. Login to the camera using the username
admin
. The first time the camera is
accessed you will need to set a password.
4. AvertX cameras are set to DHCP by default. If a DHCP server is
not detected after 4 minutes, the camera will default to IP address
192.168.51.2.
5. For assistance connecting directly to your camera, please contact AvertX
support at 855-228-3789
MICRO SD CARD AND RESET BUTTON
Your camera is equipped with a slot for a microSD card and a Reset button.
To access these, you must remove the microSD / Reset cover.
If you have purchased a microSD card to be used for backup, insert the
formatted card into the slot. Refer to the user manual for compatible cards
and how to properly format your microSD Card.
The reset button will return the camera to factory default settings. To reset
your camera, power cycle the camera then push and hold the reset button for
10 seconds. This has to be performed immediately after the camera has been
powered on or the reset will fail.
37026AA
Reset button
microSD slot
Contact AvertX Support: 1-855-228-3789 | www.avertx.com
For more information on installing your AvertX camera, download the
user manual, read FAQs and DIY resources, and view instructional videos
at www.avertx.com.
FOR FURTHER INSTRUCTIONS: