AVerMedia
®
Technologies, Inc. Product Guide
11
3.6
Ability of Power Provision
The ability of carrier board to provide power is listed in Table 5.
Table 5:
Symbol
Min.
Max.
Total Power
DC Jack Input
6V
14.9V
60W(Max.)
3.7
Thermal Specifications
The case temperature of key components is listed in Table 6.
Table 6:
Components
Components Case Temperature Specifications
USB 3.1 Gen 1 Hub
Controller (U6)
Tcase = 95
℃
DP to HDMI Protocol
Converter (U40)
Tcase = 95
℃
3.8 EMI Specifications
EMI/EMS test specification are listed in Table 7
Table 7
:
Criteria
Specification
Reference
EMI
EN55022 standard
CE
EMS
ESD test standard
EN61000-4-2
3.9 Buttons and Indicators
Buttons (Switches)
Button
Description
Usage
SW2
Reset button
Used to force a full system reset.
SW5
Volume down (Sleep)
button
Used to put system into sleep mode.
SW7
Recovery button
Used to enter Force Recovery Mode. Button is held
down while either system is first powered on, or
by pressing & releasing reset button while
Recovery button is pressed.
SW3
Power button
Used to power system up if off, or power down if
on. If held for >10 seconds, will force a full system
power cycle.