Avenview FO-HDM-1000M-EMI User Manual Download Page 8

www.avenview.com 

 

Storage Temperature 

VST 

-20 

70 

°C 

Relative Humidity 

HRH 

10 

80 

RH 

 

 

2.3 Signal Pin Assignment 

 

Transmitter / Receiver 

Pin 

Signal Assignment 

Pin 

Signal Assignment 

T.M.D.S. Data2+ 

    11 

T.M.D.S Clock Shield 

T.M.D.S. Data2 Shield 

12 

T.M.D.S Clock - 

T.M.D.S. Data2- 

    13 

CEC 

T.M.D.S. Data1+ 

14 

No Connect 

T.M.D.S. Data1 Shield 

15 

SCL 

T.M.D.S. Data1- 

16 

DSA 

T.M.D.S. Data0+ 

17 

DDC/CEC Ground 

T.M.D.S. Data1 Shield 

18 

+5V Power 

T.M.D.S. Data0- 

19 

Hot Plug Detect 

10 

T.M.D.S Clock + 

 

 

 

 

 

Stresses greater than those listed under “Absolute Maximum Ratings” may cause 
permanent damage to the device. This is a stress rating only and functional operation of 
the device at these or any other conditions above those indicated in the operations section 
for extended periods of time may affect reliability. 

Summary of Contents for FO-HDM-1000M-EMI

Page 1: ...roduct descriptions at any time without notice No license whether express implied or otherwise to any intellectual property rights is granted by this publication Except as set forth in Avenview Standa...

Page 2: ...y Instructions 3 1 3 Regulatory Notices Federal Communications Commission FCC 4 1 4 Introduction 4 1 5 Package Contents 4 1 6 Before Installation 4 1 7 Installation 5 Section 2 Specifications 6 2 1 Ca...

Page 3: ...uctions The Avenview FO HDM 1000M EMI HDMI Extender SET over Single Fiber Optic has been tested for conformance to safety regulations and requirements and has been certified for international use Howe...

Page 4: ...00 Transmit up to 1000m 3300 feet at 720p 1280 x 720 by multi mode SC Type one fiber optic cable Transmit up to 500m 1650 feet at 1920 x 1200 by multi mode SC Type one fiber optic cable TMDS video sig...

Page 5: ...ansmitter should be connected to computer and the Receiver should be connected to a monitor Avenview FO HDM 1000M EMI is designed to self detect the resolution of the monitor and change the resolution...

Page 6: ...1200 700 meters 2300 feet 1280 x 720 720p 1000 meters 3300 feet Optical Converter 4 Ch 850 nm Transmit OSA 911nm 1 Ch VCSEL 980nm 1 Ch PIN P D Diode 4 Ch 850 nm Transmit OSA 911nm 1 Ch VCSEL 980nm 1 C...

Page 7: ...www avenview com 7 2 1 Case Dimensions 2 2 Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Power Supply VCC 0 3 5 5 V Operating Temperature VOT 0 50 C...

Page 8: ...No Connect 5 T M D S Data1 Shield 15 SCL 6 T M D S Data1 16 DSA 7 T M D S Data0 17 DDC CEC Ground 8 T M D S Data1 Shield 18 5V Power 9 T M D S Data0 19 Hot Plug Detect 10 T M D S Clock Stresses great...

Page 9: ...www avenview com 9 2 4 Optical Fiber Cable The construction of 4 Optical Fibers and 4 Copper wires cable shall be in accordance with Figure and Table below...

Page 10: ...atory profits or for punitive incidental or consequential damages in connection with the furnishing performance or use of the Avenview hardware software or other products and documentation provided he...