background image

VID

ALARM

8CH

COM

 

Reference

 

Manual

 

 

4

 

 

5.Board

 

LED

 

Indication

 

 

Alarm

 

out

 

LED,

 

light

 

means

 

relay

 

closed,

 

off

 

means

 

relay

 

open

 

 

Alarm

 

in

 

LED,

 

long

 

light

 

means

 

in

 

arm

 

setup

 

status,

 

blinking

 

means

 

arming

 

 

Communication

 

LED,

 

LED

 

blinks

 

when

 

the

 

communication

 

mode

 

is

 

in

 

accordance

 

with

 

the

 

host

 

computer

 

protocol.

 

 

6.Connection

 

Operate

 

as

 

following

 

figure

 

to

 

connect

 

alarm

 

probe,and

 

connect

 

a

 

resistance(2K)in

 

series

 

connection

 

at

 

NO

 

contact.

 

S=signal,

=ground

 

wire

 

 

 

7.Protocol

 

setting

  

You

 

will

 

see

 

J1&j2

 

on

 

the

 

board

 

as

 

you

 

open

 

the

 

box

 

(the

 

number1

 

means

 

open

 

circuit,

 

number

 

0

 

means

 

short

 

circuit)

 

 

No.

 

Protocol

 

J1

 

J2

 

Note

 

0

 

DCTRLS

 

0

 

0

 

Setting

 

from

 

address

 

0

 

1

 

RM110

 

0

 

1

 

 

2

 

W110

 

1

 

0

 

 

3

 

SE600

 

1

 

1

 

The

 

address

 

of

 

channel

 

1~8

 

is

 

0,channel

 

9~16

 

is

 

1

 

 

Summary of Contents for VID-ALARM-8CH-COM

Page 1: ...or moisture 3 Do not expose to flammable explosive or corrosive gas 4 Avoid exposure to dust or other particles that may get inside the equipment 5 Use of extension cords may significantly increase ri...

Page 2: ...rew d Power Adapter Additional Items Included Back Panel Front Panel Brief Introduction Alarm in 8 port Normal Open Normal Close Input Voltage 0 15V Alarm out 8 port Normal Open Normal Close connector...

Page 3: ...channel relay outputs NO Alarm linkage function Watchdog function auto reset function in strong reference environment Open circuit and short circuit arm function Provide protocol 16 ID setting connec...

Page 4: ...dance with the host computer protocol 6 Connection Operate as following figure to connect alarm probe and connect a resistance 2K in series connection at NO contact S signal ground wire 7 Protocol set...

Page 5: ...ing please refers to the table below The number 1 means the DIP switch setting should be ON and the number 0 means OFF Note the ID number is binary digit ID Switch number 1 2 3 4 0 0 0 0 0 1 0 0 0 1 2...

Page 6: ...0 0F D2 A0 A7 A8 A15 A 0 15 is corresponding to outputs 1 16 1 ON 0 OFF Note 1 The data4 data5 of this alarm box is 0 NOTES ____________________________________________________________________________...

Page 7: ...be certain to have full details about your Aventura products available including model and invoice numbers Service Any service required by this unit should be performed by Aventura or authorized servi...

Reviews: