background image

Page 8 

1

. WARNING: FLUID MEDIA 

AVENTICS pneumatic devices are designed and tested for use 
with  filtered,  clean,  dry,  chemical  free  air  at  pressures  and 
temperatures  within  the  specified  limits  of  the  device.  For  use 
with  media  other  than  air  or  for  human  life  support  systems, 
AVENTICS must be consulted. Hydraulic cylinders are designed 
for operation with filtered, clean, petroleum based hydraulic fluid; 
operation using fire-resistant or other special types of fluids may 
require special packing and seals. Consult the factory. 

2. WARNING: MATERIAL COMPATIBILITY  

Damage  to  product  seals  or  other  parts  caused  by  the  use  of 
noncompatible  lubricants,  oil  additives  or synthetic lubricants  in 
the  air  system  compressor  or  line  lubrication  devices  voids 
AVENTICS  warranty  and  can  result  in  product  failure  or  other 
malfunction. See lubrication recommendations below. 

AIR  LINE  LUBRICANTS! 

In service higher than 18 cycles per 

minute  or  with  continuous flow  of  air  through the  device,  an  air 
line lubricator is recommended.* (Do not use line lubrication with 
vacuum  products.)  However,  the  lubricator  must  be  maintained 
since the oil will wash out the grease, and lack of lubrication will 
greatly  shorten  the  life  expectancy.  The  oils  used  in  the 
lubricator must be compatible with the elastomers in the device. 
The  elastomers  are  normally  BUNA-N,  NEOPRENE,  VITON, 
SILICONE  and  HYTREL.    AVENTICS  recommends  the  use  of 
only  petroleum  based  oils  without  synthetic  additives,  and  with 
an aniline point between 180° F and 210° F.  

COMPRESSOR  LUBRICANTS! 

All  compressors  (with  the 

exception of special "oil free" units) pass oil mist or vapor from 
the  internal  crankcase  lubricating  system  through  to  the 
compressed  air.  Since  even  small  amounts  of  non-compatible 
lubricants  can  cause  severe  seal  deterioration  (which  could 
result  in  component  and system  failure)  special care should  be 
taken in selecting compatible compressor lubricants.  

3. WARNING: INSTALLATION AND MOUNTING 

The  user  of  these  devices  must  conform  to  all  applicable 
electrical, mechanical, piping and other codes in the installation, 
operation or repair of these devices. 

NSTALLATION  ! 

Do  not  attempt  to  install,  operate  or  repair 

these devices without proper training in the technique of working 
on  pneumatic  or  hydraulic  systems  and  devices,  unless  under 
trained  supervision.    Compressed  air  and  hydraulic  systems 
contain high levels of stored energy. Do not attempt to connect, 

disconnect  or  repair  these  products  when  a  system  is  under 
pressure.  Always  exhaust  or  drain  the  pressure  from  a  system 
before performing any service work.  Failure to do so can result 
in serious personal injury. 

MOUNTING! 

Devices should be mounted and positioned in such 

a manner that they cannot be accidentally operated. 

4. WARNING: APPLICATION AND USE OF PRODUCTS 

The  possibility  does  exist for  any  device  or  accessory  to fail to 
operate properly through misuse, wear or malfunction. The user 
must consider these possibilities and should provide appropriate 
safe  guards  in  the  application  or  system  design  to  prevent 
personal injury or property damage in the event of a malfunction. 

5. WARNING: CONVERSION, MAINTENANCE AND REPAIR 

When  a  device  is  disassembled  for  conversion  to  a  different 
configuration, maintenance or repair, the device must be tested 
for  leakage  and  proper  operation  after  being  reassembled  and 
prior to installation. 

MAINTENANCE  AND REPAIR! 

Maintenance periods should be 

scheduled  in  accordance  with  frequency  of  use  and  working 
conditions. All AVENTICS products should provide a minimum of 
1,000,000  cycles  of  maintenance  free  service  when  used  and 
lubricated as recommended. However, these products should be 
visually inspected for defects and given an "in system" operating 
performance  and  leakage  test  once  a  year.  Where  devices 
require a major repair as a result of the one million cycles, one 
year,  or  routine  inspection,  the  device  must  be  disassembled, 
cleaned,  inspected,  parts  replaced  as  required,  rebuilt  and 
tested for leakage and proper operation prior to installation. See 
individual catalogs for specific cycle life estimates. 

6. PRODUCT CHANGES 

Product changes including specifications, features, designs and 
availability are subject to change at any time without notice. For 
critical dimensions or specifications, contact factory. 
*Many  AVENTICS  pneumatic  valves  and  cylinders  can  operate 
with  or  without  air  line lubrication; see  individual sales catalogs 
for details. 
 

NOTICE TO PRODUCT USERS

 

LIMITATIONS OF WARRANTIES & REMEDIES

 

AVENTICS warrants its products sold by it to be free from defects in material and workmanship to the following: 
For  twelve  months  after  shipment  AVENTICS  will  repair  or  replace  (F.O.B.  our  works),  at  its  option,  any  equipment  which  under 
normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser.  No charge will 
be  made  for  labor  with  respect  to  defects  covered  by  this  Warranty,  provided  that  the  work  is  done  by  AVENTICS  or  any  of  its 
authorized  service  facilities.    However,  this  Warranty  does  not  cover  expenses  incurred  in  the  removal  and  reinstallation  of  any 
product, nor any downtime incurred, whether or not proved defective. 
All  repairs  and  replacement  parts  provided  under  this  Warranty  policy  will  assume  the  identity,  for  warranty  purposes,  of  the  part 
replaced, and the warranty on such replacement parts will expire when the warranty on the original part would have expired.   Claims 
must be submitted within thirty days of the failure or be subject to rejection. 
This Warranty is not transferable beyond the first using purchaser.  Specifically, excluded from this Warranty are failures caused by 
misuse, neglect, abuse, improper operation or filtration, extreme temperatures, or unauthorized service or parts.  This Warranty also 
excludes the use of lubricants, fluids or air line additives that are not compatible with seals or diaphragms used in the products.  This 
Warranty  sets  out  the  purchaser's  exclusive  remedies  with  respect  to  products  covered  by  it,  whether  for  negligence  or  otherwise.  
Neither, AVENTICS nor any of its affiliates will be liable for consequential or incidental damages or other losses or expenses incurred 
by reason of the use or sale of such products.  Our liability (except as to title) arising out of the sale, use or operation of any product or 
parts,  whether  on  warranty,  contract  or  negligence  (including claims  for  consequential  or  incidental damage)  shall  not  in  any  event 
exceed the cost of replacing the defective products and, upon expiration of the warranted period as herein provided, all such liability is 
terminated.    THIS  WARRANTY  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES,  EXPRESS  OR  IMPLIED,  WHETHER  FOR 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE.  No attempt to alter, amend or extend this 
Warranty shall be effective unless authorized in writing by an officer of AVENTICS Corporation. 
AVENTICS reserves the right to discontinue manufacture of any product, or change product materials, design or specifications without 
notice.

 

Reviews: