Assembling the LP04 PROFIBUS DP
34
AVENTICS
| PROFIBUS DP | R402000616–BDL–001–AF
The switches must not be changed during operation.
Changed switch positions will only become valid, after the
device has been turned off and restarted.
6.1
Observe the following with manual
addressing
The units and tens digits for the module addresses are switched
by the rotary switches (refer to Fig. 1).
Addresses from 2 to 99 are allowed.
O
Unscrew the caps of the rotary switches, tens and units.
O
Address the rotary switches by turning with a screwdriver.
– See Table 8 for LED functions.
Table 5:
Addressing the bus coupler
Switch
Address
1
SW2
tens digits
2
SW1
unit digit
3
Not used
Table 6:
Byte X is the start address of the output section for this module in the pilot control.
Byte
Regarding
Bit
7
6
5
4
3
2
1
0
X
Valve
4
4
3
3
2
2
1
1
Coil
12
14
12
14
12
14
12
14
X + 1
Valve
8
8
7
7
6
6
5
5
Coil
12
14
12
14
12
14
12
14
X + 2
Valve
12
12
11
11
10
10
9
9
Coil
12
14
12
14
12
14
12
14
X + 3
Valve
16
16
15
15
14
14
13
13
Coil
12
14
12
14
12
14
12
14
Summary of Contents for PROFIBUS DP
Page 2: ......
Page 4: ...Inhalt 4 AVENTICS PROFIBUS DP R402000616 BDL 001 AF ...
Page 24: ...Contents 24 AVENTICS PROFIBUS DP R402000616 BDL 001 AF ...
Page 42: ...Sommaire 42 AVENTICS PROFIBUS DP R402000616 BDL 001 AF ...
Page 62: ...Indice 62 AVENTICS PROFIBUS DP R402000616 BDL 001 AF ...
Page 82: ...Índice 82 AVENTICS PROFIBUS DP R402000616 BDL 001 AF ...
Page 102: ...Innehåll 102 AVENTICS PROFIBUS DP R402000616 BDL 001 AF ...