W
Single subbase 5610211052:
to the top side of the base plate using two through
holes .
Required mounting material:
– 2 M6x40 screws,
tightening torque 8 Nm with bolt grade 8.8
– 2 washers
W
Single subbase (5610231002): to the side of the base
plate using two through holes
.
Required mounting material:
– 2 M8x60 screws,
tightening torque: 23 Nm with bolt grade 8.8
– 2 washers
W
Sandwich base 8985049932:
The linked sandwich bases are fastened to the
assembly surface using the left and right end plates.
Required mounting material: depends on end plate
O
You can find the exact dimensions of the mountings for
your base plate in the online catalog from AVENTICS
(www.aventics.com/pneumatics-catalog).
O
Install the base plate in your system in a manner where
the pneumatic connections are always accessible.
O
Fasten the base plate to the assembly surface so that
it is not under any stress. While doing so, observe the
maximum permissible tightening torque values for the
mounting screws.
Inserting the base plate seal in the pressure
regulator
1.
Place the base plate seal (
–
2
) on the lower side of
the ED07 pressure regulator so that the three
pneumatic ports are not covered.
2.
Gently press down on the base plate seal so it is fixed
on the three mounting pins (
–
3
) in the pressure
regulator.
The three mounting pins ensure that the base plate
seal is placed correctly on the contour of the
pneumatic ports.
Placing the pressure regulator on a base plate
A coded pin (
–
5
) is located on the base plate, which fits
in the coded hole (
–
4
) of the ED07 pressure regulator.
This ensures correct assembly.
1.
Turn the ED07 pressure regulator so that the coded pin
(
–
5
) and coded hole (
–
4
) are on the same side
and the pin can be inserted into the hole.
Suitable own mounting material must be used in
order to fasten the base plates to the assembly
surface. The general rules of technology apply
here.
The sandwich base has two coded pins. This is
why there is a second coded hole on the same side
of the ED07 pressure regulator. Mix-ups are ruled
out by this.
3
4
5
5
5
6
6
6
6
6
2.
Place the ED07 pressure regulator on the base plate.
Make sure that the base plate seal does not slide out of
place.
The coded pin on the base plate will fit into the coded
hole in the ED07 pressure regulator.
Screwing the pressure regulator onto the
base plate
1.
Insert the four M5x90 screws in the four through holes
of the pressure regulator as shown in the figure and
screw them into the threaded holes of the base plate.
Tightening torque: 6 Nm
2.
Check again that the base plate seal is fitted properly
to ensure the IP 65 protection class.
The base plate seal may not protrude on the sides.
Connecting the base plate pneumatics
O
For information on how to connect the pneumatics,
please see the instructions for the ED07 pressure
regulator R414001671.
7
Disassembly and Disposal
Disassembling the base plate
1.
Make sure the relevant system part is not under
voltage or pressure. Slowly exhaust the system to
avoid uncontrolled movements.
2.
Remove the pneumatic connections from the base
plate.
3.
Remove the pressure regulator and base plate from
the assembly surface. The disassembly order depends
on the type of base plate.
NOTICE
Incorrect valve mounting!
Valves may be damaged!
O
Observe the maximum tightening torque values and
check that all screws and bolts are properly
tightened.
You can find the pneumatic connection technology
for base plate tubing in the online catalog.
CAUTION
Danger of burns caused by hot surfaces!
Touching the surfaces of the valves during operation
could lead to burns.
O
Let the valves cool off before disassembling the
base plate.
O
Do not touch the valves during operation
7
9
AVENTICS
| ED07 | R414006606–BDL–001–AB | English
8