www.factorybuysdirect.com
200264-01B
10
Figure 5 - Moving Thermostat Sensing
Bulb
Figure 6 - Removing Front Panel
INSTALLATION
Bulb Clip
Thermostat
Sensing
Bulb
1. Pull out the sensing bulb from the two clips
located in the shipping position. There is
no need to take out the two bulb clips.
2. Take out the bulb clip from the hardware
package and insert it into the square hole.
Then insert the sensing bulb into the bulb
clip (see Figure 5).
FASTENING HEATER TO WALL
INSTALLING THERMOSTAT SENSING BULB (OPTIONAL)
REMOVING FRONT PANEL
Screw
Front
Panel
1. Remove 4 screws securing front panel.
2. Carefully slide front panel forward.
Mounting Bracket
The mounting bracket is located on back panel
of heater. It has been taped there for shipping.
Remove mounting bracket from back panel.
Methods For Attaching Mounting
Bracket To Wall
Use only the last hole on each end of mount-
ing bracket to attach bracket to wall. Attach
mounting bracket to a wall only in one of two
ways:
1.
Attaching to wall stud:
This method pro-
vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.
2.
Attaching to wall anchor:
This method
allows you to attach mounting bracket to
hollow walls (wall areas between studs)
or to solid walls (concrete or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall where
heater will be located. Make sure mount-
ing bracket is level.
WARNING: Maintain mini-
mum clearances shown in Figure
4, page 9. If you can, provide
greater clearances from floor
and joining wall.