Avenger 110061 Owner'S Operation And Installation Manual Download Page 9

www.factorybuysdirect.com

9

200406-01B

INSTALLATION

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri

-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

  WARNING: A  qualified  ser

-

vice person must install heater. 

Follow all local codes.

 WARNING: Never install the 

heater

•  in  a  bathroom.  10,000  BTU/

Hr units can be installed in a 

bedroom.

•  in a recreational vehicle

• where curtains, furniture, 

clothing,  or  other  flammable 

objects are less than 36" from 

the front, top, or sides of the 

heater

•  in high traffic areas

•  in windy or drafty areas

 CAUTION: This heater cre-

ates  warm  air  currents.  These 

currents move heat to wall sur

-

faces next to heater. Installing 

heater next to vinyl or cloth wall 

coverings  or  operating  heater 

where  impurities  (such  as  to

-

bacco smoke, aromatic candles, 

cleaning fluids, oil or kerosene 

lamps, etc.) in the air exist, may 

cause walls to discolor.

Figure 4 - Mounting Clearances as 

Viewed From Front of Heater

IMPORTANT:

 Vent-free heaters add moisture 

to the air. Although this is beneficial, installing 

heater in rooms without enough ventilation air 

may cause mildew to form too much moisture. 

See 

Air for Combustion and Ventilation

, pages 

7 and 8.

CHECK GAS TYPE

Be sure your gas supply is right for your heat-

er. Otherwise, call dealer where you bought 

the heater for proper type heater.

CLEARANCES TO 

COMBUSTIBLES

Carefully follow the instructions below. This 

heater is a freestanding unit designed to be 

mounted on a wall or set on a base.

 WARNING: Maintain the 

minimum clearances shown in 

Figure  4.  If  you  can,  provide 

greater  clearances  from  floor, 

ceiling, and joining wall.

LOCATING HEATER

This heater is designed to be mounted on a 

wall. For convenience and efficiency, install 

heater:
1.  Where there is easy access for operation, 

inspection, and service.

2.  In the coldest part of room.
When installing the appliance directly on car-

peting, tile or other combustible material other 

than  wood  flooring,  the  appliance  shall  be 

installed on a metal or wood panel extended 

the full width and depth of the appliance.

CEILING

36"

Minimum

6"

Minimum

From

Sides of

Heater

Left

Side

Right

Side

2" Minimum to Top Surface of Carpeting,

Tile or Other Combustible Material

FLOOR

Summary of Contents for 110061

Page 1: ...o not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructi...

Page 2: ...515 8 011 920 7 967 006 7 967 007 7 654 820 7 730 765 7 677 236 7 607 426 7 434 447 This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for ad eq...

Page 3: ...ease or anemia those under the influ ence of alcohol and those at high altitudes NATURALAND PROPANE GAS Natural and Propane gas are odorless An odor making agent is added to the gas The odor helps you...

Page 4: ...ter off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately...

Page 5: ...FA 110064 FDTL20BFA Ignition Piezo Piezo Gas Type Natural Propane Maximum Input Rating 20 000 BTU Hr 20 000 BTU Hr Minimum Input Rating 10 000 BTU Hr 10 000 BTU Hr Pressure Regulator Setting 4 W C 9 W...

Page 6: ...ion Inc 1 Batterymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the use of vent free heaters State of Massachusetts The i...

Page 7: ...quate combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than e...

Page 8: ...ation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors T...

Page 9: ...use walls to discolor Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without eno...

Page 10: ...shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach mounting bracke...

Page 11: ...fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations usi...

Page 12: ...ling Bottom Mounting Screws Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 10 2 Place heater onto mounting bracket Slide horizontal slots onto stan...

Page 13: ...al regulator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane gas CAUTION Avoid damage to regulator Hold gas re...

Page 14: ...heater valves The installer must supply an external regula tor The external regulator will reduce incom ing gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do...

Page 15: ...f gas supply piping system Apply mixture of liquid soap and water to gas joints If bubbles form there may be a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas su...

Page 16: ...any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call t...

Page 17: ...UTION Do not try to ad just heating levels by using the equipment shutoff valve THERMOSTAT CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats You set stand...

Page 18: ...gure 20 Incorrect Pilot Flame Pattern IMPORTANT Owner s should check pilot flame pattern and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance...

Page 19: ...l forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front panel using screws re moved in step 2 ODS PILOT Periodically inspect a...

Page 20: ...g ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 19 or replace ODS pilot assembly 5 Check inlet ga...

Page 21: ...r ODS pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 19 2 Contact local gas supplier Delayed ignition of burner s 1 Manif...

Page 22: ...r produces un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page20 2 Gas leak See Warning State ment at the top of page 20 3 Low fuel supply propane ga...

Page 23: ...k you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free a...

Page 24: ...www factorybuysdirect com 200406 01B 24 2 11 3 7 1 8 10 5 6 4 12 9 13 PARTS MODEL SKU FDTN10BFA 110061 FDTL10BFA 110062...

Page 25: ...161132 01 161132 01 Mounting Bracket 1 3 ML083 03 ML083 03 Piezo Ignitor 1 4 161130 01 161130 01 Thermostat Valve 1 5 Burner Assembly 1 6 162332 03 ODS Pilot Natural Gas 1 162332 01 ODS Pilot Propane...

Page 26: ...www factorybuysdirect com 200406 01B 26 2 11 3 1 8 10 6 12 7 5 4 Thermostat Valve 9 13 PARTS MODEL SKU FDTN20BFA 110063 FDTL20BFA 110064 FDTN30BFA 110065 FDTL30BFA 110066 20 000 BTU Hr Model Shown...

Page 27: ...ing Bracket 1 3 ML083 03 ML083 03 ML083 03 ML083 03 Piezo Ignitor 1 4 161130 01 161130 01 161130 01 161130 01 Thermostat Valve 1 5 Burner Assembly 1 6 162332 04 162332 04 ODS Pilot NG 1 162332 02 1623...

Page 28: ...st of part s required to restore this product to proper operating condition and an allowance for labor when provided by a Factory Buys Direct Authorized Service Center or a provider ap proved by Facto...

Reviews: