14
– Inductive load (cos
ϕ
= 0.4): 5A – 230Vac
– Filament lamps: 600W max.
– Fluorescent lamps: 300W max. (power factor rised in parallel)
• Loads to be controlled with direct current:
– Resistive load: 5A – 300 Vdc/0.5 A – 100 Vdc
• Load trigging time: 4 s to 5 min (10% tolerance)
• Twilight threshold adjustment: 10 lx to 3.000 lx.
• Luminous push button input max load:
– 4mA (nr. 5 0220 lamps or nr. 15 0230 lamps)
• Overall dimensions: nr. 2 System 45 modules
• Protection degree: IP41
STANDARD REFERENCES
CEI EN 60669-2-1 " Circuit breakers for domestic fixed installations and similar uses"
COVERING DIAGRAM
• Standard lens
(fig. 2 a)
• Optional lens
(fig. 2 b)
C.392 18-10-2004 09:52 Pagina 14