background image

International Trademark registration n° 

327040 - 942905 - 330600

Instructions for Use

Touchscreen chronothermostat - battery power supplied

CRONOTC1B / CRONOTC2B / CRONOTC3B

Summary of Contents for CRONOTC1B

Page 1: ...International Trademark registration n 327040 942905 330600 Instructions for Use Touchscreen chronothermostat battery power supplied CRONOTC1B CRONOTC2B CRONOTC3B...

Page 2: ...OFF function 10 Winter operation 11 Summer operation 11 Preset programs 12 Chronothermostat programming 12 Preset parameter reset 13 Displaying the temperature detected by the separate probe 13 Stati...

Page 3: ...day of the week NOTE Temperature perceived is calculated according to the following formula Where H is the perceived temperature T is the effective air temperature Values in brackets represent the em...

Page 4: ...n used for the Programming or Copy or Statistical data displaying functions 7 Rotary selector for temperature correction T1 Manual temperature Jolly temperature and antifreeze temperature 8 Rotary sel...

Page 5: ...em ON in Summer operation 7 System ON in Winter operation 8 Relative humidity percentage 9 Perceived temperature displayed by the degree 10 Ambient external temperature 11 Current day 1 Monday 7 Sunda...

Page 6: ...currently used will be interrupted temporarily Choose the time setting function 2 Modify the hour setting by means of the and buttons then go to the minute setting by means of the button 3 Modify the...

Page 7: ...four different operating modes Manual Automatic Holiday and Jolly in addition to the OFF function Manual operating mode With the Manual operating mode the chronothermostat adjusts the operation of the...

Page 8: ...annot be lower than temperature T2 or higher than 40 C In Summer operation mode the upper limit of temperature T3 is 30 C When this value is exceeded T3 will take the OFF value which will involve swit...

Page 9: ...rogram refer to Chronothermostat programming pag 35 Jolly operating mode With the Jolly operating mode the chronothermostat interrupts the current operating mode and adjusts the operation of the heati...

Page 10: ...9 You can interrupt the Jolly mode at any time by selecting any other operating mode The Jolly operating mode can be used for instance to save energy by lowering the temperature when the house is not...

Page 11: ...emperatures The Antifreeze temperature can be modified from 2 C to 7 C by 0 1 C increments by using either one of the three rotary switches on the right side of the chronothermostat If a temperature o...

Page 12: ...erating modes so as to adapt them to your own needs To set new temperature profiles proceed as follows 1 Enter the programming menu main page The operating mode currently used will be interrupted temp...

Page 13: ...med Reset default parameters To resume the preset temperature profiles and values T1 T2 T3 Temperature used with the Manual mode Temperature used with the Jolly mode Antifreeze temperature OFF functio...

Page 14: ...tal number of hours during which the system has been switched on and operating since its first start up 16 hours in the image Use the button to go to the next page Press the and buttons simultaneously...

Page 15: ...t pag 41 and batteries are not replaced within 15 days the chronothermostat will turn off automatically and the display will show the message OFF or On instead of the temperature value Settings and da...

Page 16: ...d with a base suitable for wall mounting or for flush mounting in three module rectangular or round boxes SPACING DIMENSIONS FOR FIXING THE BASE Separate the base from the chronothermostat levering on...

Page 17: ...ect the two wires of the heating or air conditioning system to the terminals 1 and 2 as shown in the figure Terminals are suitable for flexible cables with screw 2 5 mm2 max section Terminal 4 is free...

Page 18: ...ress by hand the chronothermostat onto the base make sure the multi pole connector fits properly The chronothermostat will click into position Configuring the chronothermostat Warning The chronothermo...

Page 19: ...ation parameter values keep keys key 1 and key 2 pressed simultaneously for about 4 seconds Index Parameter Writing Values Preset value 1 Type of connected card COn rEL rAd none 2 Temperature scale CE...

Page 20: ...ue according to the thermal gradient of the system broadband for high gradients narrow band for low gradients Regulation period To set the regulation cycle length ON period OFF period when the proport...

Page 21: ...rs of the advance switch on time calculated by optimization Pump anti seizure To turn the system on for 1 minute a day h 23 58 thereby operating the water circulation pump and preventing it from seizi...

Page 22: ...mm two pole jack plug Insulation Double Protection degree IP20 Setting storage Non volatile memory Micro disconnection 1BU Software A Class Temperature regulation range 2 C 40 C Anti freeze temperatu...

Page 23: ...23 ENGLISH Notes...

Page 24: ...etween contacts When tightening the terminal screws special care should be taken to avoid overheating which could start a re or damage the cables The product must be used in dry dust free areas Suitab...