Avaya VSP 4000 Series Installing Download Page 32

Use only power cords that have a grounding path. Without a proper ground, a person who
touches the switch is in danger of receiving an electrical shock. Lack of a grounding path to the
switch can result in excessive emissions. For a translation of this statement, see 

Translations of

safety messages

 on page 38.

Connect power to the rear panel

Connect the AC power cord to the rear of the switch, and then connect the cord to an AC power
outlet. The following figure shows how to connect the AC power cord to the switch rear panel.

Important:

The Avaya VSP 4000 series has no AC power switch. When you connect the power cord to a
suitable, energized AC power outlet, the switch powers up immediately.

Figure 6: Connecting AC power to the rear panel

Warning:

Disconnecting the AC power cord is the only way to turn off AC power to the Avaya VSP 4000.
Always connect the AC power cord in a quickly and safely accessible location in case of an
emergency. For a translation of this statement, see 

Translations of safety messages

 on

page 38.

Installing the Avaya VSP 4000 4450GSX series

November 2016

Installing Avaya Virtual Services Platform 4450GSX-PWR+ Switch

32

Comments on this document? [email protected]

Summary of Contents for VSP 4000 Series

Page 1: ...Installing Avaya Virtual Services Platform 4450GSX PWR Switch Release 5 1 NN46251 307 Issue 07 04 November 2016...

Page 2: ...TO BIND SUCH ENTITY TO THESE TERMS OF USE IF YOU DO NOT HAVE SUCH AUTHORITY OR IF YOU DO NOT WISH TO ACCEPT THESE TERMS OF USE YOU MUST NOT ACCESS OR USE THE HOSTED SERVICE OR AUTHORIZE ANYONE TO ACC...

Page 3: ...CT TO CODECS IF THE AVAYA CHANNEL PARTNER IS HOSTING ANY PRODUCTS THAT USE OR EMBED THE G 729 CODEC H 264 CODEC OR H 265 CODEC THE AVAYA CHANNEL PARTNER ACKNOWLEDGES AND AGREES THE AVAYA CHANNEL PARTN...

Page 4: ...0 24 Installation and removal of Small Form Factor Pluggable SFP transceivers 24 Installing SFP transceivers 24 Removing SFP transceivers 25 RJ 45 connector pin assignments 25 Connector pin assignment...

Page 5: ...ort 43 Documentation 43 Training 43 Viewing Avaya Mentor videos 43 Searching a documentation collection 44 Subscribing to e notifications 45 Contents November 2016 Installing Avaya Virtual Services Pl...

Page 6: ...iewing Avaya Mentor videos Avaya Mentor videos provide technical content on how to install configure and troubleshoot Avaya products About this task Videos are available on the Avaya Support website l...

Page 7: ...to or changed on the Avaya Support website About this task You can subscribe to different types of general notifications for example Product Correction Notices PCN which apply to any product or a spec...

Page 8: ...l through the list and then select the product name 9 Select a release version 10 Select the check box next to the required documentation types Introduction November 2016 Installing Avaya Virtual Serv...

Page 9: ...ic product and software release to perform searches across an entire document collection For example you can perform a single simultaneous search across the collection to quickly find all occurrences...

Page 10: ...Case Sensitive Include Bookmarks Include Comments 6 Click Search The search results show the number of documents and instances found You can sort the search results by Relevance Ranking Date Modified...

Page 11: ...no feature related changes for VOSS 5 1 in Installing Avaya Virtual Services Platform 4450GSX PWR Switch NN46251 307 November 2016 Installing Avaya Virtual Services Platform 4450GSX PWR Switch 11 Com...

Page 12: ...4400A05 E6 with a EU power cord EC4400B05 E6 Same content as EC4400A05 E6 with a UK power cord EC4400C05 E6 Same content as EC4400A05 E6 with a JP power cord EC4400D05 E6 Same content as EC4400A05 E6...

Page 13: ...upport additional power requirements or to provide power redundancy The following table describes the Avaya Virtual Services Platform 4000 compatible AC and DC power supplies and their part numbers or...

Page 14: ...us media types You can use various SFP 1Gb s and SFP 10Gb s to attain different line rates and reaches The following table describes the SFPs including the reach provided by various SFPs Important The...

Page 15: ...cts see Installing Transceivers and Optical components on VSP Operating System Software NN47227 301 Supported optical devices November 2016 Installing Avaya Virtual Services Platform 4450GSX PWR Switc...

Page 16: ...ports with PoE 2 36 100 1000 Mbps SFP ports 3 two 1 10G SFP ports Figure 1 VSP 4450GSX PWR 1 USB 2 0 port Note The VSP 4450GSX PWR model does not require a USB device in the USB port for normal operat...

Page 17: ...EDs 3 10 100 1000 Base TX RJ 45 ports 4 100 1000 Mbps SFP ports 5 1 10G SFP ports 6 Console Port Electrostatic discharge This section provides information and procedures to prevent electrostatic disch...

Page 18: ...the nearest reliable ground is typically at the electrical outlet Avoid contact between equipment and clothing The wrist or ankle strap protects only the equipment from ESD voltages on the body ESD vo...

Page 19: ...ht 4 4 cm 1U 4 4 cm 1U Width 44 cm 44 cm Depth 43 6 cm 43 68 cm Weight 17 2lbs 7 80 kg with 1 PSU installed A PSU weighs 3 1 lbs 1 40 kg 17 2lbs 7 80 kg with 1 PSU installed A PSU weighs 3 1 lbs 1 40...

Page 20: ...h side of the switch unit for ventilation Adequate clearance at the front and rear of the switch for access to cables Warning To avoid bodily injury from hazardous electrical shock and current never r...

Page 21: ...50GSX Quick Install Guide NN46251 303 d The China RoHS paper Installing the Avaya Virtual Services Platform 4000 on a table or shelf You can install a single Avaya VSP 4000 switch on any flat surface...

Page 22: ...imeters at the back for power cord clearance Installing the Avaya Virtual Services Platform 4000 in an equipment rack To install an Avaya VSP 4000 switch in an equipment rack perform this procedure In...

Page 23: ...rack is grounded to the same grounding electrode used by the power service in the area The ground path must be permanent and must not exceed 1 Ohm of resistance from the rack to the grounding electrod...

Page 24: ...nector so a serial cable with RJ 45 connectors or a serial cable with a DB 9 female connector on one end and an RJ 45 on the other is appropriate The maximum length for the console port cable is 25 fe...

Page 25: ...om the module slot 4 If the transceiver does not slide easily from the module slot use a gentle side to side rocking motion while firmly pulling the transceiver from the slot 5 Attach a dust cover ove...

Page 26: ...in IEEE802 3at Console port pin assignments The following table describes the console port pin assignments in the Avaya VSP 4000 Important Avaya VSP 4000 supports only CLI Quickstart use on the conso...

Page 27: ...X series switches This section describes the regulatory AC and DC power specifications for the Avaya VSP 4000 4450GSX series switches The following table describes the regulatory AC power specificatio...

Page 28: ...ications for the Avaya Virtual Services Platform 4000 on page 27 Power supply power specifications for the VSP 4450GSX series switches The Avaya VSP 4450GSX series switches support two external field...

Page 29: ...er supply 1835W with two power supplies 17 8W or 32 4W 802 3 at 1 power supply The VSP 4450GSX PWR can support 802 3af 17 8W or 32 4W on each port with one power supply installed You can add a second...

Page 30: ...only applies to hardware models with field replaceable power supplies 1 If a blanking plate covers the required power supply slot remove the blanking plate before attempting to insert the power supply...

Page 31: ...ons Country and Plug Specification Specifications Typical Plug Continental Europe CEE7 standard VII male plug Harmonized cord HAR marking on the outside of the cord jacket to comply with the CENELEC H...

Page 32: ...cord to the switch rear panel Important The Avaya VSP 4000 series has no AC power switch When you connect the power cord to a suitable energized AC power outlet the switch powers up immediately Figur...

Page 33: ...ing all processes CP1 03 24 14 18 39 08 000 LifeCycle INFO All processes have stopped CP1 03 24 14 18 39 08 000 LifeCycle INFO All applications shutdown starting power down sequence INIT Sending proce...

Page 34: ...00 The figures and tables in the following sections describe the LEDs on the Avaya Virtual Services Platform 4000 switches The tables describe LED operation for a switch that finishes the power on sel...

Page 35: ...y Normal operation Off The switch is not receiving power and not operating Status Green solid During start up The power on self test POST is complete and the switch is operating normally After start u...

Page 36: ...et link Speed indicates the port speed for example 10 Mb s 100 Mb s 1000 Mb s Table 15 RJ 45 Port LED state indicators Label Color and Status Description Speed PoE Green Blink The port is set to opera...

Page 37: ...ists Note If you connect two ports explicitly set for different speeds for example one configured as 10BaseT and the other as 100BaseTX the port link LED may indicate a link but the switch does not es...

Page 38: ...ctement sur un autre Chaque module doit tre fix sa propre baie l aide des supports de montage appropri s Ces supports ne sont pas con us pour r sister plusieurs modules Important Precauti n Cuando mon...

Page 39: ...e veillez laisser la plaque m tallique sur la baie Si vous la retirez l a ration du module ne peut pas s effectuer correctement Important Precaution Si no instala ning n m dulo en la ranura aseg rese...

Page 40: ...Advertencia Para apagar el dispositivo debe desenchufar el cable Conecte siempre el cable de alimentaci n a una toma segura y de f cil acceso por si se produjera alguna situaci n de emergencia Import...

Page 41: ...per la messa a terra Senza un adeguata messa a terra chiunque tocchi lo switch corre il rischio di ricevere una scossa elettrica L assenza di un percorso per la messa a terra verso lo switch pu compo...

Page 42: ...sistencia para cambiar la bater a Important Aviso A bateria de l tio n o substitu vel em campo S deve ser removida e substitu da por pessoal autorizado Entre em contato com o Suporte T cnico da Avaya...

Page 43: ...tion Reference for a list of documentation for all VOSS products For installation and initial setup information of the Open Networking Adapter ONA refer to the Quick Install Guide that came with your...

Page 44: ...ection On the Avaya Support website you can download the documentation library for a specific product and software release to perform searches across an entire document collection For example you can...

Page 45: ...for example Product Correction Notices PCN which apply to any product or a specific product You can also subscribe to specific types of documentation for a specific product for example Application Te...

Page 46: ...ll through the list and then select the product name 9 Select a release version 10 Select the check box next to the required documentation types Resources November 2016 Installing Avaya Virtual Servic...

Page 47: ...11 Click Submit Subscribing to e notifications November 2016 Installing Avaya Virtual Services Platform 4450GSX PWR Switch 47 Comments on this document infodev avaya com...

Reviews: