![Avaya Virtual Services Platform 7200 Series Installation Manual Download Page 15](http://html.mh-extra.com/html/avaya/virtual-services-platform-7200-series/virtual-services-platform-7200-series_installation-manual_3028206015.webp)
3. Remove the fan tray that failed by pushing the tab on the spring latch to the left and pulling
on the fan’s extraction handle.
4. Insert the new fan tray into the chassis.
Important:
You can hot swap fan trays while the switch is operational.
5. Verify that the fan tray is fully seated in the chassis. The spring latch should engage and
return to its original position.
6. Enter the following command to check the temperature sensors inside the switch.
show sys-info temperature
Example
Check the status of the fan trays.
VSP-7254XSQ:1>show sys-info fan
Fan Info :
Fan Id Fan Status Fan Type
---------------------------------------
1 up regularSpeed
2 up regularSpeed
3 up regularSpeed
Check the internal temperature of the switch.
VSP-7254XSQ:1>show sys-info temperature
Temperature Info :
CPU Temperature MAC Temperature PHY1 Temperature PHY2 Temperature
26 29 24 27