Maintenance Commands
555-233-143
7-260
Issue 1 May 2002
reset ipserver-interface
reset ipserver-interface
Uc
This command performs a board reset for an IPSI in the named cabinet/carrier.
This is equivalent to reset board Ucss.
NOTE:
The IPSI must be busied out before a reset is allowed. If you attempt to
send the reset ipserver-interface command without busying out the IPSI, an
error message reminds you. Use the busy ipserver-interface command to
take the IPSI out of service.
Parameters
Examples
reset ipserver-interface 2a
Output
U
cabinet (1-64)
Specify the cabinet number with the board you want to
test.
c
carrier
Supply the carrier you want to test.
reset ipserver-interface 2a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02A TONE-BD 53 PASS
Command successfully completed