Signaling
Issue 1 May 2002
1-21
555-233-143
Quantization Distortion Loss
lists the quantization distortion loss in the system for analog port to
analog port.
lists the quantization distortion loss in the system for analog port to
digital port and digital port to analog port.
Terminating Impedance: 600 Ohms nominal
Trunk balance impedance (selectable): 600 Ohms nominal or complex Z
[350 Ohms + (1 k Ohms in parallel with 0.215uF)]
Impulse Noise
On 95% or more of all connections, the impulse noise is 0 count (hits) in 5 minutes
at +55 dBrnC (decibels above reference noise with C-filter) during the busy hour.
Table 1-11.
Quantization Distortion Loss
Analog Port-to-Analog Port
Signal Level
Distortion Loss
0 to -30 dBm0
>33 dB
-40 dBm0
>27 dB
-45 dBm0
>22 dB
Table 1-12.
Quantization Distortion Loss
Analog Port-to-Digital Port or
Digital Port-to-Analog Port
Signal Level
Distortion Loss
0 to -30 dBm0
>35 dB
-40 dBm0
>29 dB
-45 dBm0
>25 dB