AVAYA Merlin Legend
5
• The next screen asks you to select the hunt type. Choose
Circular
.
• Press exit to return to the Group Calling menu.
Assign the MAS ports as members of the calling group:
Assign the MAS ports as
members of the calling group
• From the Group Calling menu, select
Members
.
• Next, enter the extension number just assigned to the MAS calling
group. Press enter to save your entry.
• At the “Enter group members” prompt, specify the first MAS port
with
one
of the following:
-extension number nnnn (will be 2, 3, 4 digits, etc.)
-slot and port number
*
sspp
-logical ID number
#
nnn
• If the MAS ports are in sequential number, press the
Next
key to add
the next MAS port. I f the MAS ports are not sequential, press
Enter
to add the next MAS port. Repeat until all MAS ports have been
added to the calling group.
• When all MAS ports have been added, verify your entries by using
the
Inspect
key on the console. (If you are using a PC to program
the Legend, press PgDn and then the F5 key.) This will list all
members of the calling group.
• Press exit to return to the Group Calling menu.
Assign the Group Type for the MAS calling group. This parameter tells
the Legend to send mailbox ID information on calls to the MAS
system. In addition, it will automatically log in the MAS ports after a
power
failure.
Assign the Group Type for the
MAS calling group
• At the Group Calling menu, select
More
to see the second page of
the menu.
• From the Group Calling menu, select
Group Type
.
• Enter the extension number of the MAS calling group. Press
enter
to save your entry.
• At the next screen, select
Integ VMI
. Press
enter
to save your
selection.
• To return to the Extensions menu, press exit twice.
The above information is provided by AVAYA Inc. as a guideline. See disclaimer on page 1