Disassociating a clock source
Procedure
To disassociate an interface previously specified as the primary or secondary clock
synchronization source, enter
clear sync interface primary
or
clear sync
interface secondary
.
Enabling and disabling automatic failover and failback
Procedure
To enable or disable automatic failover and failback between designated primary and
secondary synchronization sources, enter
set sync switching enable
or
set
sync switching disable
.
Synchronization status
The yellow ACT LED on the front of the MM710 media module displays the synchronization
status of that module.
• If the yellow ACT LED is solidly on or off, it has not been defined as a synchronization
source. If it is on, one or more channels is active. If it is an ISDN facility, the D-channel
counts as an active channel and causes the yellow ACT LED to be on.
• When the MM710 is operating as a clock synchronization source, the yellow ACT LED
indicates that the MM710 is the clock synchronization source by flashing at three second
intervals, as follows:
- The yellow ACT LED is on for 2.8 seconds and off for 200 milliseconds if the MM710
media module has been specified as a clock synchronization source and is receiving
a signal that meets the minimum requirements for the interface
- The yellow ACT LED is on for 200 milliseconds and off for 2.8 seconds if the MM710
media module has been specified as a synchronization source and is not receiving
a signal, or is receiving a signal that does not meet the minimum requirements for
the interface
Synchronization
Administering Avaya G430 Branch Gateway
October 2013 607
Summary of Contents for G430
Page 1: ...Administering Avaya G430 Branch Gateway Release 6 3 03 603228 Issue 5 October 2013 ...
Page 12: ...12 Administering Avaya G430 Branch Gateway October 2013 ...
Page 246: ...VoIP QoS 246 Administering Avaya G430 Branch Gateway October 2013 Comments infodev avaya com ...
Page 556: ...IPSec VPN 556 Administering Avaya G430 Branch Gateway October 2013 Comments infodev avaya com ...