Avaya Ethernet Routing Switch 8300 Series Installation Manual Download Page 1

Installation — DC Power Supply

Avaya Ethernet Routing Switch 8300

4.2

NN46200-310, 02.03

May 2011

Summary of Contents for Ethernet Routing Switch 8300 Series

Page 1: ...Installation DC Power Supply Avaya Ethernet Routing Switch 8300 4 2 NN46200 310 02 03 May 2011...

Page 2: ...TO DO SO YOU ON BEHALF OF YOURSELF AND THE ENTITY FOR WHOM YOU ARE INSTALLING DOWNLOADING OR USING THE SOFTWARE HEREINAFTER REFERRED TO INTERCHANGEABLYAS YOU AND END USER AGREE TO THESE TERMS AND COND...

Page 3: ...c of Korea only 8 National Safety Statements of Compliance 8 CE Marking Statement Europe only 8 NOM Statement 8310 and 8306 Chassis Mexico only 9 Informaci n NOM nicamente para M xico 9 Denan Statemen...

Page 4: ...ibutor or reseller 37 Getting technical support from the Avaya Web site 38 Chapter 7 Translations of safety messages 39 Notices 39 Chapter 8 Technical specifications 45 Technical specifications naviga...

Page 5: ...national standards as detailed below National Electromagnetic Compliance EMC Statements of Compliance FCC Statement USA only This equipment has been tested and found to comply with the limits for a Cl...

Page 6: ...glement sur le brouillage radio lectrique du minist re des Communications du Canada CE Marking Statement Europe only EN 55 022 Statements This is to certify that the Avaya 8300 Series chassis and com...

Page 7: ...nd European Free Trade Association EFTA Notice All products labeled with the CE marking comply with R TTE Directive 1999 5 EEC which includes the Electromagnetic Compliance EMC Directive 2004 108 EC a...

Page 8: ...mmunications MIC This device may not be sold for use in a non business application National Safety Statements of Compliance CE Marking Statement Europe only EN 60 950 Statement This is to certify that...

Page 9: ...VAC 12 A 47 to 60 Hz per power supply 8302AC 200 to 240 VAC 10 A 47 to 60 Hz per power supply single supply single supply one redundant supply two supplies or two supplies one redundant supply config...

Page 10: ...una fuente redundante 8005DC 48 to 60 VDC 42 to 34 A una fuente una fuente configuraciones de una fuente redundante dos fuentes o dos configuraciones de una fuente redundante Denan Statement Japan Nip...

Page 11: ...SD ESD Hinweise bieten Information dazu wie man die Entladung von statischer Elektrizit t und Folgesch den an Avaya Produkten verhindert Electrostatic alert PRECAUCI N ESD Descarga electrost tica El a...

Page 12: ...ion PRECAUCI N Los avisos de Precauci n brindan informaci n acerca de c mo evitar posibles interrupciones del servicio o el da o a los productos Avaya Caution CUIDADO Os avisos de cuidado oferecem inf...

Page 13: ...rimentos ao trabalhar com os produtos da Avaya Warning AVVISO Le indicazioni di avviso forniscono informazioni per evitare danni alle persone durante l utilizzo dei prodotti Avaya Danger High Voltage...

Page 14: ...mazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso a causa dell alta tensione o di scosse elettriche Danger Notice Danger Danger notices provide i...

Page 15: ...o ou condi o que possa causar graves ferimentos ou morte Danger PERICOLO Le indicazioni di pericolo forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle...

Page 16: ...Regulatory Information and Safety Precautions 16 Installation DC Power Supply May 2011...

Page 17: ...ge 17 DC power supply Added Attention to the section Ethernet Routing Switch 8300 series chassis in the DC power supply fundamentals chapter Customer Service Customer service chapter is added to this...

Page 18: ...see NOM Statement 8310 and 8306 Chassis Mexico only on page 9 and Informaci n NOM nicamente para M xico on page 9 New in this Release 18 Installation DC Power Supply May 2011...

Page 19: ...s are required to take appropriate measures necessary to correct the interference at their own expense For the minimum Ethernet Routing Switch 8300 software version required to support the hardware se...

Page 20: ...nutes for each power supply Replacing the DC power supply cover 1 minute for each power supply Navigation DC power supply fundamentals on page 21 DC power supply installation on page 25 Technical spec...

Page 21: ...the power supply Light Emitting Diode LED on the DC power supply Table 2 Power supply LED State Description Off No output is present On green Power supply output is normal DC power supply accessories...

Page 22: ...hassis DC power supplies The 8306 and 8310 chassis each have three power supply bays in which you can install either the 8005DC or the 8005DI DC power supply If the total power provided by the power s...

Page 23: ...rays must not exceed the 8005DI DC power supply rating To determine the minimum number of power supplies to install for the Ethernet Routing Switch 8300 system see Determining the minimum number of DC...

Page 24: ...ant power configuration and one power supply fails the chassis continues to operate with no interruption of service The chassis continues to supply the same module output power with the remaining powe...

Page 25: ...circuits Prerequisites Verify that you have the following tools and materials cable crimping tool for crimping the lugs onto the cable heat gun to shrink the tubing around the cable optional 7 16 inc...

Page 26: ...the minimum number of DC power supplies on page 27 Preparing cables for installation on page 27 Removing the power filler panel on page 28 Installing the DC power supply on page 29 DC power supply in...

Page 27: ...ndant power supply needs If one power supply satisfies your system power consumption needs a second power supply provides redundancy If two power supplies satisfy your system power consumption needs a...

Page 28: ...the Ethernet Routing Switch 8300 chassis You must remove the power filler panel from the power bay when you install a power supply in a bay for the first time Caution To maintain proper cooling never...

Page 29: ...power source of the Ethernet Routing Switch 8300 Caution Risk of equipment damage To prevent damage from electrostatic discharge always wear an antistatic wrist strap connected to an ESD jack Danger...

Page 30: ...eplacing a failed power supply remove the failed DC power supply 4 Grasp the handle of the new power supply 5 Push the new power supply partway into the bay leaving the terminal block at the side of t...

Page 31: ...e terminal Danger Risk of injury by electric shock Before you continue with this procedure ensure that the DC power source is switched off 9 Attach the earth ground lead to the ground stud on the powe...

Page 32: ...ips screwdriver to replace the plastic safety cover on the power supply 15 Firmly slide the power supply all the way into the bay See Job aid Tightening the retaining screws on the DC power supply on...

Page 33: ...urn on the power supplies simultaneously If you wait longer to turn on the supplies the power supplies shut off within 7 seconds To correct this condition turn off the power supplies for 2 minutes and...

Page 34: ...Job aid DC power supply input and ground stud location Job aid Attaching the earth ground lead to the ground stud DC power supply installation 34 Installation DC Power Supply May 2011...

Page 35: ...ghtening the retaining screws on the DC power supply Figure 2 Tightening the retaining screws on the DC power supply 8306 and 8310 chassis Installing the DC power supply Installation DC Power Supply M...

Page 36: ...DC power supply installation 36 Installation DC Power Supply May 2011...

Page 37: ...To download and print selected technical publications and release notes directly from the Internet go to www avaya com support Getting product training Ongoing product training is available For more i...

Page 38: ...om the Avaya Web site The easiest and most effective way to get technical support for Avaya products is from the Avaya Technical Support Web site at www avaya com support Customer Service 38 Installat...

Page 39: ...Dies ist ein Ger t der Klasse A Bei Einsatz des Ger ts in Wohngebieten kann es St rungen des Radio und Fernsehempfangs verursachen In diesem Fall muss der Benutzer alle notwendigen Ma nahmen ergreife...

Page 40: ...nu est adapt une utilisation avec la source d alimentation laquelle il est raccord Plusieurs crit res tels que le calibre l inflammabilit et l aptitude l usage m canique doivent tre pris en compte lor...

Page 41: ...quipment damage To prevent damage from electrostatic discharge always wear an antistatic wrist strap connected to an ESD jack Caution ATTENTION Risque d endommagement de l quipement Pour pr venir tout...

Page 42: ...c bles Voltage Pour votre s curit v rifiez que les cosses sont correctement serties sur les c bles Verletzungsrisiko durch Stromschlag Es besteht ein Sicherheitsrisiko wenn die Anschlussst cke nicht o...

Page 43: ...frigeraci n adecuada no opere Ethernet Routing Switch 8300 con el compartimiento de la fuente de alimentaci n vac o Si necesita reemplazar una fuente de alimentaci n defectuosa y no cuenta con un pane...

Page 44: ...erve el panel de relleno de energ a para utilizarlo en caso de ser necesario operar Ethernet Routing Switch 8300 sin una fuente de alimentaci n Caution CUIDADO Guarde o painel de preenchimento de ener...

Page 45: ...ings for the 8005DI DC input power supply and output power supply DC input power specifications The following table describes the technical specifications for DC input power for Model 8005DI DC power...

Page 46: ...r Bellcore TR 332 standard Model 8005DC power supply This section provides power ratings for the 8005DC input power supply and output power supply DC input power specifications The following table des...

Page 47: ...5DC power supply Table 7 DC output power specifications for Model 8005DC power supply Parameter Specifications Output power maximum 1462 W 1372 W 90 W fans Modules 3 3 V 150 A 12 V 72 A Fans 12 VDC 7...

Page 48: ...Technical specifications 48 Installation DC Power Supply May 2011...

Page 49: ...ing 29 status LEDs 21 distributor 37 documentation 37 E estimated installation time 19 H hardware shipped with the DC power supply 21 I installation DC power supply 29 L LEDs power supply 21 R reselle...

Page 50: ......

Reviews: