Maintenance Architecture
555-233-123
1-20
Issue 4 May 2002
Insertion Loss for Port-to-Port; Analog or Digital
lists the insertion loss in the system for different connection types for
the United States.
shows the overload and cross-talk characteristics.
NOTE:
The following numbers apply only to DCP or BRI station types. They do not
apply to IP stations.
Table 1-10.
Insertion Loss for the United States
Typical Connections
Nominal Loss
(dB) at 1 kHz
On-premises to on-premises station
6
On-premises to off-premises station
3
Off-premises to off-premises station
0
On-premises station to 4-wire trunk
3
Off-premises station to 4-wire trunk
2
Station-to-trunk
0
Trunk-to-trunk
0
Table 1-11.
Overload and Crosstalk
Overload level
+3 dBm0
Crosstalk loss
>70 dB