MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 4 May 2002
10-1063
555-233-123
Loss of Signal Alarm Inquiry Test (#138)
This test is meaningless for the TN802 MAPD circuit pack.
details
the test results.
PASS
The circuit pack initializes correctly.
1. Run the Short Test Sequence.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Use add ds1
UUCSS to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the
error log to determine whether the board is hyperactive. If
this is the case, the board is shut down. Reseating the board
re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Table 10-388.
Loss of Signal Inquiry Test (#138) results
Windows NT up
on the TN802?
Then
Cause
Y
Test passes
Y
Test aborts with ABORT
2000 Error Code.
Windows NT is not communicating
with the angel firmware.
N
Test aborts with ABORT
2000 Error Code.
Windows NT down.
Table 10-387.
TEST #53 SAKI Sanity Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...