Maintenance Object Repair Procedures
555-233-123
10-702
Issue 4 May 2002
LEDs
shows the 4 front panel LEDs that signal the following information:
SPE select switches
Each Duplication Interface circuit pack has a faceplate SPE-select switch with A,
B, or AUTO positions for determining which SPE is active. See
:
Table 10-255.
TN792 LED description
Color (from
top to bottom)
Explanation
Red (top)
Fault detected
Green
Maintenance routine in progress on this circuit pack
Yellow
Lit when in active carrier.
Flashing LED(s) means one of the following:
■
optical cable is not attached
■
optical cable is attached incorrectly
■
optical cable is broken
■
transmit or receive hardware on one or both circuit packs is
malfunctioning
■
one of the DUPINT circuit packs is bad
Red
SPE select switches on both Duplication Interface circuit packs
are set the same (either SPE A or SPE B).
Both switches must be in the same position for this LED to light.
Continued on next page
Table 10-256.
TN792 SPE-select positions
SPE A setting
SPE B setting
Effect
A
A
Forces carrier A active
B
B
Forces carrier B active
A
B
Software determines active carrier
1
1
If the SPE select switches are in a locked position and either or both of the Duplication
Interface circuit packs are removed, the active SPE remains active, and no
SPE-interchange occurs.
B
A
AUTO
AUTO
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...