Removing Power
Issue 4 May 2002
5-5
555-233-123
Removing Power
When power is removed, the following features deactivate:
■
Attendant Trunk Group Control
■
Automatic Callback
■
Call Park
■
Make Busy for Direct Department Calling (DDC) and Uniform Call
Distribution (UCD)
!
WARNING:
Before powering down a cabinet or carrier that contains EMBEDDED AUDIX
circuit packs (TN566), first power down the AUDIX unit to avoid damaging
the AUDIX software. Instructions for powering down this unit are in the
‘‘EMBEDDED AUDIX System Power Procedures’’
, on the circuit pack, and
in EMBEDDED AUDIX documentation.
EMBEDDED AUDIX System Power Procedures
Manually Power Down AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to shut
down the EMBEDDED AUDIX System prior to powering down the system.
1. Press the Boot/shutdown button with a pointed object, such as a paper clip
or pen (do not use a pencil). The button is located near the top right of the
front panel.
2. Press the boot/Shutdown button until the LCD display flashes the message
MSHUT.
3. Release the Boot/Shutdown button.
NOTE:
The EMBEDDED AUDIX System takes about five minutes to shut
down. The “heartbeat” indication on the display continues to flash.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...