Remove Module Control Carrier(s)
Issue 7 November 2003
5-47
555-233-115
3. Disconnect the 16 ground straps from the top and bottom of the “A” carrier.
See
. These straps reconnect to the new “A” carrier.
Figure 5-6.
Locations of Ground Jumpers
Figure Notes
1. Rear of Cabinet
2. Port Carrier (“C” Position)
3. Ground Jumpers
4. Module Control Carrier (“A” Position)
5. Port Carrier (“D” Position)