DEFINITY AUDIX Power Procedures
Issue 7 November 2003
4-65
555-233-115
DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to shut
down the DEFINITY AUDIX System prior to powering down the system.
1. Log into the AUDIX System as craft.
2. Type reset system shutdown and press
Enter
. Press
Enter
once.
NOTE:
Do not press
Enter
again. This will force the AUDIX to shutdown
immediately, dropping all active calls on the AUDIX.
3. The “SHUTDOWN Completed” message appears when the AUDIX is
successfully shutdown. This takes about 2 minutes.
4. The AUDIX System can now be removed for service.
Power Up the AUDIX System
■
If the AUDIX was removed from the cabinet:
1. Re-install the AUDIX and allow it to boot up automatically.
2. Check for AUDIX System errors.
■
If the AUDIX remained in the cabinet but power was removed from the
cabinet:
1. Power up the cabinet. The AUDIX reboots automatically.
2. Check for AUDIX System errors.
■
If the AUDIX remained in the cabinet and the cabinet was not powered
down:
1. At the AUDIX console, hold the
crtl
key and type cc.
2. Type 5 at the prompt. In about 2 minutes, the AUDIX boots up.
3. When the system initialization is complete, log in as craft.
4. Check for AUDIX System errors.