Budgeting Power
Note:
Note:
One APC 800W PSU provides enough power for a stack of ten C363T and/or
C364T switches.
When deciding how many 800W PSUs to install in the APC external DC power shelf, you need
to take into account the configuration of the powerinline external power parameter in the
C360-PWR switch (set using the
set powerinline external power
CLI command).
for guidelines:
If you set the powerinline external power parameter to other values, you need to recalculate the
number of switches supported accordingly.
Table 10: Budgeting Power - C363T-PWR
No. of APC
PSUs
No. of C363T-PWR switches
supported
Power requirement: 350W
1
2
2
4
3
6
Table 11: Budgeting Power - C364T-PWR
No. of APC
PSUs
No. of C364T-PWR switches
supported
Power requirement = 600W
1
1
2
2
3
4