background image

ArgentWAN3

Hardware Reference Manual (Revision 4)

Summary of Contents for ArgentWAN3

Page 1: ...ArgentWAN3 Hardware Reference Manual Revision 4 ...

Page 2: ...s All rights reserved No part of this publication may be reproduced transcribed stored in an electronic retrieval system translated into any language or computer language or be transmitted in any form whatsoever without the prior written consent of Avaya Inc Notice Avaya Inc makes no endorsement of any particular product for any purpose nor claims any responsibility for its operation and accuracy ...

Page 3: ...ns 10 LAN Port 10 DTE Port 10 DC Power Input Connector 10 Connection to an X 21 V 35 or V 24 V 28 Leased Line 11 Further Information and Product Updates 12 Section 2 Technical Data Port Pinouts 14 DTE Port 25 way D Type Socket 14 LAN Port 10 baseT RJ45 Socket 14 WAN Port 37 way D Type Socket 15 Cables 16 LAN Interconnect Cable 16 LAN Cable 17 V 24 V 28 WAN Cable 18 X 21 WAN Cable 19 V 35 WAN Cable...

Page 4: ...ArgentWAN3 Hardware Reference Manual 4 Revision 4 ...

Page 5: ...rgentWAN3 This section contains y About the ArgentWAN3 page 6 y Safety and Homologation Statements page 7 y Product Variants page 8 y Port Labelling page 9 y Port Connections page 10 y Further Information and Product Updates page 12 ...

Page 6: ... integrated voice and data system with features otherwise only available on expensive call centre systems The Alchemy Series Argent family will enhance your communications by bringing voice and data integration to your desktop provide you with a range of systems designed to make you more effective and allow you to enjoy the fruits of your consequent success This Reference Manual provides technical...

Page 7: ...Section 1 Introduction to ArgentWAN3 Revision 4 7 SAFETY AND HOMOLOGATION STATEMENTS DECLARATION OF CONFORMITY y Please see the associated Declaration of Conformity document within the Approvals folder ...

Page 8: ...rial Synchronous data WAN ports y 1 x Serial Asynchronous data port This port is used for factory purposes y 1 x 10BaseT LAN port This port is used to Interconnect the ArgentWAN3 to the ArgentOffice The 10BaseT LAN port is located on the front of the unit all the other ports are located on the rear of the unit CURRENT COUNTRY VARIANTS The unit is currently available for the UK and European markets...

Page 9: ...e ports on the ArgentWAN3 ARGENTWAN3 FRONT VIEW The following diagram shows the port labelling on the front of the ArgentWAN3 WAN Unit LAN LAN Link Status Status Link OK Activity LEDs LED LED LED ARGENTWAN3 REAR VIEW The following diagram shows the port labelling on the rear of the ArgentWAN3 ...

Page 10: ...e need for a crossover cable If the ArgentWAN3 is located in the same cabinet as the ArgentOffice it can be connected to one of the hub ports on the ArgentOffice via a LAN Interconnect cable Sales Feature ARG HSIC Part No CABETHNN01M0PP00 DTE PORT The DTE port is presented as a standard 25 way D Type socket on the rear of the unit This port is used as a diagnostic aid This port is labelled DTE DC ...

Page 11: ...sed Circuit is made by connecting the WAN port on the rear of the ArgentWAN3 to the supplied Network Terminating Unit NTU via the appropriate X 21 V 35 or V 24 cable This cable can be purchased from any Alchemy Series reseller distributor by ordering the appropriate Sales Feature as detailed in the table below or the user can supply his own cable so long as the criteria set out in Cables page Erro...

Page 12: ...on 4 FURTHER INFORMATION AND PRODUCT UPDATES Further information including Product and Reference Manual updates can be obtained from Avaya Inc Alchemy Dealers and Distributors or from Avaya Inc Alchemy web site http www avaya co uk products alchemy ...

Page 13: ...Section 2 Technical Data This section contains y Port Pinouts page 14 y Cables page 16 y Port Safety Classification page 22 y Rack Mount Assembly Instructions page 23 y Technical Specifications page 24 ...

Page 14: ...n 1 Pin 25 Pin No Description Signal Direction 2 Transmit Data TxD Í 3 Receive Data RxD Î 4 Request to Send RTS Í 5 Clear to Send CTS Î 6 Data Set Ready DSR Î 7 Signal Ground 8 Data Carrier Detect DCD Î LAN PORT 10 BASET RJ45 SOCKET Pin 1 Pin 8 Pin No Description Signal Direction 1 Receive Data Tx A Î 2 Receive Data Tx B Î 3 Transmit Data Rx A Í 6 Transmit Data Rx B Í ...

Page 15: ...Clk B Í 4 V11 Tx A Î 23 V11 Tx B Î 5 V11 Ctl B Î 24 V11 Ctl A Î 6 V11 Gnd 25 WAN ID 0 Í 7 WAN ID 1 Í 26 V24 Tx Î 8 V24 DTR Î 27 V24 RTS Î 9 V24 Rx Í 28 V24 RxClk Í 10 V24 TxClk Í 29 V24 RI Í 11 V24 DCD Í 30 V24 DSR Í 12 V24 CTS Í 31 N C 13 N C 32 V35 Tx A Î 14 V35 Tx B Î 33 V35 SCTE A Î 15 V35 SCTE B Î 34 V35 Gnd 16 V35 Rx B Í 35 V35 Rx A Í 17 V35 TxClk B Í 36 V35 TxClk A Í 18 V35 RxClk B Í 37 V35...

Page 16: ...eature ARG HSIC A RJ45 Plug B RJ45 Plug C Cat 5 UTP cable GREEN D 1 metre Pin Connections End A Colour Cable Notes End B 1 White Orange 1 2 Orange White 2 3 White Green 3 6 Green White 6 This cable is supplied with the ArgentWAN3 It is used to connect the ArgentWAN3 to one of the ArgentOffice LAN hub ports when the two units are co located in the same cabinet D A B C Twisted pair Twisted pair ...

Page 17: ...etre Pin Connections End A Colour Cable Notes End B 1 White Orange 1 2 Orange White 2 3 White Green 3 6 Green White 6 4 Blue White 4 5 White Blue 5 7 White Brown 7 8 Brown White 8 This cable is used when connecting the ArgentWAN3 to a LAN hub port which is not co located in the same cabinet D A B C Twisted pair Twisted pair Twisted pair Twisted pair ...

Page 18: ...eened with tinned copper braid maximum working voltage of 440V r m s and a Maximum current per core of 1A r m s D 3 metres Pin Connections End A Name End B 6 Ground 7 8 DTR Data Terminal Ready 20 9 Receive Data 3 10 Transmit Clock 15 11 DCD Data Carrier Detect 8 12 CTS Clear To Send 5 26 Transmit Data 2 27 RTS Request To Send 4 28 Receive Clock 17 29 RI Ring Indicator 22 30 DSR Data Set Ready 6 Co...

Page 19: ...F m impedance of 77 Ω at 1MHz screened with aluminised tape and a tinned copper wire drain D 3 metres Pin Connections End A Name Cable Notes End B 1 Receive Rx B 11 20 Receive Rx A 4 4 Transmit Tx A 2 23 Transmit Tx B 9 24 Control Ctl A 3 5 Control Ctl B 10 2 Indicate Ind A 5 21 Indicate Ind B 12 3 SE Timing S A 6 22 SE Timing S B 13 6 Ground 8 Connect pin 7 to pin 6 at End A only Pin 19 at end A ...

Page 20: ...pper stranded wire nominal capacitance of 98pF m impedance of 80 Ω 10 at 1MHz screened with aluminised tape and a tinned copper wire drain D 3 metres Pin Connections End A Name Cable Notes End B 8 DTR Data Terminal Ready H 11 DCD Data Carrier Detect F 12 CTS Clear To Send D 27 RTS Request To Send C 29 RI Ring Indicator J 30 DSR Data Set Ready E 32 Transmit Data A P 14 Transmit Data B S 35 Receive ...

Page 21: ... B AA 37 Receive Clock A V 18 Receive Clock B X 33 External Clock A U 15 External Clock B W 34 Ground B Connect pins 7 and 25 to pin 6 at End A only Pin 19 at end A is connected to the Screened Cable Drain Wire The maximum core to core capacitance must not exceed 800pF Twisted pair Twisted pair Twisted pair ...

Page 22: ...sification DTE port Async Data connection SELV WAN port WAN connection NET TNV Operating within the limits of SELV LAN port 10BaseT attachment to LAN SELV DC Input port Connector for DC input power SELV Interconnection circuits shall be selected to provide continued conformance with the requirements of EN 609050 1992 A3 1995 clause 2 3 for SELV circuits and with the requirements of clause 6 for TN...

Page 23: ...Section 2 Technical Data Revision 4 23 RACK MOUNT ASSEMBLY INSTRUCTIONS ...

Page 24: ...x 37 way D Type female socket X 21 interface to 2048k bps V 35 interface to 2048k bps and V 24 Interface to 19k2 bps Dimensions Width 445mm Height 71mm Depth 245mm Environmental 0 to 40 C 95 relative humidity non condensing Weight Unit PSU 3 10 Kg Unit only 2 80Kg Power 2 5mm DC inlet socket 12Vdc Power input Rating 12Vdc 1A max The Power Adapter is CE Safety Approved The unit s power consumption ...

Page 25: ...power input connector 10 digital leased circuit 11 dimensions 24 DTE port 10 14 22 E EMC 7 environment 24 european directives 7 F firewall 8 H help text files 6 I installation wizard 6 interfaces 24 IP router 8 ISDN 6 7 L LAN cable 17 LAN interconnect cable 16 LAN port 10 14 22 locking screws 18 19 20 low voltage directive 7 N notification body 7 NTU 11 P part number CABETHNN01M0PP00 16 CABETHNN03...

Page 26: ... ARG WANX21C 19 SELV 22 T technical data 13 interfaces 24 port safety classification 22 rack mount assembly instructions 23 specifications 24 technical specifications 24 terminal directive 7 V V 24 V 28 WAN cable 18 V 28 leased line 11 V 35 leased line 11 V 35 WAN cable 20 voice integration 6 W WAN port 15 22 weight 24 windows 2000 6 windows 95 6 windows 98 6 windows NT4 6 X X 21 leased line 11 X ...