![Avaya 8308XL Planning And Engineering Download Page 27](http://html1.mh-extra.com/html/avaya/8308xl/8308xl_planning-and-engineering_3027926027.webp)
your configuration. For the 8005DI DC power supply specifications, see
on page 29.
3. Consider your redundant power supply needs. If one power supply satisfies your
system power consumption needs, a second power supply provides redundancy. If
two power supplies satisfy your system power consumption needs, a third power
supply provides redundancy.
AC power supply specifications
This section describes the power specifications for the Ethernet Routing Switch 8301AC and
8302AC power supplies.
Navigation
•
8301AC power supply specifications
•
8302AC power supply specifications
8301AC power supply specifications
The maximum steady-state output power is limited to a total of 1140 W for any combination of
output voltages/currents at low-line 100-120 VAC nominal input voltage conditions.
The maximum steady-state output power is limited to a total of 690 W for any combination of
output voltages/currents, excluding the 50 VDC source at low-line 100-120 VAC nominal input
voltage conditions. This limitation is required to ensure that you have sufficient PoE power or
450 W total at this input voltage condition.
The maximum steady-state output power is limited to a total of 870 W for any combination of
output voltages or currents, excluding the 50 VDC source at high-line 200-240 VAC nominal
input voltage conditions. This limitation is required to ensure maximum PoE power or 900 W
total for the 50 VDC source at this input voltage condition.
To obtain the full output power rating of 1770 W, you must connect the power supply to a
nominal (200-240 VAC) input voltage source.
The following table specifies individual AC input and DC output power ratings for each 8301AC
power supply.
Table 4: 8301AC power specifications
AC input power ratings
Input voltage range (nominal)
100-120 VAC
200-240 VAC
AC power supply specifications
Planning and Engineering — Power Considerations
May 2011 27
Summary of Contents for 8308XL
Page 18: ...New in this release 18 Planning and Engineering Power Considerations May 2011 ...
Page 20: ...Introduction 20 Planning and Engineering Power Considerations May 2011 ...
Page 32: ...Power considerations 32 Planning and Engineering Power Considerations May 2011 ...
Page 36: ...Power cord specifications 36 Planning and Engineering Power Considerations May 2011 ...
Page 42: ...Translation of safety messages 42 Planning and Engineering Power Considerations May 2011 ...
Page 44: ......