3.6.7 Platform fences 

They must conform to EN 14122, be 1,1 m high and 
be equipped with doors. These must be monitored 
with a trapped key system that permits fence door to 
be opened only when service lift is present. 
Trapped key is attached to cabin by means of a wire 
rope, preventing loss of key. 

Optionally, the platform fences can be equipped  
with an electrical switch monitoring system, that 
disables control of the elevator in case one platform 
fence is open, which is composed by a manual 
actuated mechanical lock connected to switch 
cutting power to lift when it is opened, or with a 
guardlocking system keeping the door locked while 
the service lift is not at the platform. The door is 
unlocked when the service lift is at the platform with
the lift detection switch activated. The ready light is 
ON when the door is closed. 
During emergency use, for example, power cut, need 
of evacuation or rescue, the door guard locking 
switch can be unlocked by acting the mechanical 
Door Manual Release system from outside the fence, 
or from inside the fence.

3.6.8 Main service lift door

 

Main access to the cabin is done through the full 
sliding door installed on the front. 
The full sliding door opening dimensions are 1950 x 
500 mm. It features a guard locking system that:

• Prevents service lift to travel if the door is open.
This opening condition is monitored by the guard
locking switch.

• Permits door to be opened only when service lift
is levelled with a platform. This levelling condition is
monitored by the platform level switch which is
triggered by the safe zone plates.

For the Octopus L95, as an option, the levelling 
condition can be monitored by a magnetic sensor.

It is possible to manually release guard locking 
system in order to open main door between 
platforms for maintenance tasks or installation of 
WTG parts. 

3.6.9 Ladder access door

 

Ladder access door consists of two hinged sheets 
that fold up when opened, thus optimizing space. In 
case of evacuation, the ladder access door permits 
direct access to ladder and ladder rail. 
A safety switch interrupts control when door is open.

External manual release of 
guard locking of L95

Internal manual release of 
guard locking of L95

External manual release 
of guard locking of L95

Internal manual release 
of guard locking of L95

Platform level 
switch

Safe zone plate  
(on all platforms)

A

A

B

B

C

C

D

D

E

E

F

F

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

TH

IS

DO

CU

ME

NT

AN

D

ITS

CO

NT

EN

TS

AR

E

PR

OP

RI

ET

AR

Y

TO

AI

P

Ap

S

AN

D

PR

OT

EC

TE

D

BY

CO

PY

RI

GH

T.

TH

EY

AR

E

CO

NF

ID

EN

TIA

LA

ND

MA

Y

CO

NT

AI

N

LE

GA

LL

Y

PR

IV

ILE

GE

D

IN

FO

RM

AT

IO

N.

CO

PY

IN

G,

SU

BM

ITT

IN

G

TO

TH

IR

D

PA

RT

IE

S

OR

US

E

IN

AN

Y

FO

RM

AN

D

FO

R

AN

Y

PU

RP

OS

E

OT

HE

R

TH

AN

TH

AT

OR

IG

IN

AL

LY

IN

TE

ND

ED

IS

PR

OH

IB

ITE

D

W

ITH

OU

TT

HE

EX

PR

ES

S

PR

EV

IO

US

W

RI

TT

EN

CO

NS

EN

TO

FA

IP

Ap

S.

Denmark

Rønnevangs Allé 6

DK-3400 Hillerød

AIP ApS

Stamp:

Material:

Dimension:

Edit by:

Edge:

Constructor:

Surface:

Title:

Revsion note:

Measure tolerance:

Replaced by:

Date:

Sign:

Replaces:

Drw. no.

Valid from:

Rev.no.:

Release

Scale:

Weight:

ISO 2768-mK

Proj:

Format:

A3

ISO-E

kg

1 / 1

Sheet no.

Summary of Contents for OCTOPUS L95

Page 1: ...AVANTI SERVICE LIFT User s Manual Model Service Lift OCTOPUS L95 Original instructions ...

Page 2: ...CE certificate for Octopus L95 ...

Page 3: ...Systems Technology S L Calle Ángeles Los Num 88 Pol Industrial Centrovía 50198 Muela La Zaragoza Spain P 34 976 149524 F 34 976 149508 E info avanti online com I www avanti online com Manufactured Under Process Patent NO 8 499 896 Registered in Europe Sales Service avanti online com contact ...

Page 4: ...evice 14 3 6 14 Top obstruction device 15 3 6 15 Top normal limit switch 15 3 6 16 Manual descent system 15 3 6 17 Overload limiter 15 3 6 18 Internal light 16 3 6 19 Warning lights 16 3 6 20 Anchor points 16 3 6 21 Rescue pendant control 16 3 6 22 Information signs and documents 16 3 6 23 Travelling cable pulley 17 3 6 24 Fasten kit 17 4 Instructions for use 18 4 1 Daily inspection 18 4 2 Prohibi...

Page 5: ... ii has not been installed operated repaired or maintained in accordance with this Manual or other instructions from Avanti iii has been subjected to abuse neglect casualty or negligence iv has been furnished by Avanti to Customer without charge or v has been sold on an AS IS basis Except as specifically set forth in this Limited Warranty ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRA...

Page 6: ...om any changes in the manuals does not entitle Customer to any form of compensation or other legal remedies The pictures and sketches in this manual may not reflect the product aesthetics colours arrangement precisely This has no impact on the function or safety STOP Symbol Signal word Meaning Possible injury if not observed Safety instructions DANGER IMMEDIATE or possibly imminent danger Death or...

Page 7: ...nicians Personnel must be at least 18 years of age The staff must be familiar with the relevant accident prevention instructions and must have received proper training in these Personnel are obliged to read and understand this User s Manual Personnel shall wear PPE safety helmet full body harness shock absorber lanyard and slider at all times A copy of the User s Manual must be handed out to the p...

Page 8: ...g temperature ranges in particular there is a standard configuration and a low temperature configuration where traction system and main control box components are chosen specifically 3 3 Exclusions The service lift shall not be used outdoor or in potentially explosive atmospheres The service lift is not designed to carry a person on its top The wind turbine manufacturer is responsible of integrati...

Page 9: ...9 User s Manual 3 5 Dimensions 1040 2680 2750 970 960 ...

Page 10: ... light 4 Anchor points 5 Maintenance cover 6 Cabin control box 7 Bottom obstruction device 8 Guide ladder 9 Guiding rollers 10 Main control box 11 Hour counter 12 Ladder access door 13 Full sliding door 14 External controls 15 Top obstruction device 16 Safety wire rope 17 Traction wire rope 18 Travelling cable pulley ...

Page 11: ...1 8 4 1 8 4 50 Octopus L95 M508 690V 60Hz 500 21 1 8 2 8 8 4 55 Traction system Fall arrest device 3 6 3 Fall arrest device 3 6 4 Traction and safety wire ropes Service Lift Fall arrest device Lifting capacity Safety wire rope Ø Unit weight approx Version Type Kg lbs mm Kg lbs OctopusL95 ASL 508 500 1100 8 4 7 15 4 Service Lift Version Wire rope type Wire rope diameter Surface Treatment Mark featu...

Page 12: ...for send function Override key of bottom obstruction switch DOWN button Platform level lamp Ready lamp Emergency stop button UP button Main switch Fall arrest device triggered lamp Internal DOWN button for manual function Internal UP button for manual function Trapped key switch optional for Octopus L95 Internal emergency stop button Platform level lamp OK lamp Overload buzzer Warning buzzer Hour ...

Page 13: ...vice lift door Main access to the cabin is done through the full sliding door installed on the front The full sliding door opening dimensions are 1950 x 500 mm It features a guard locking system that Prevents service lift to travel if the door is open This opening condition is monitored by the guard locking switch Permits door to be opened only when service lift is levelled with a platform This le...

Page 14: ...a safety switch that interrupts control when hatch is opened Top obstruction device hatch opens outwards Once top hatches and ladder access door are open clear area is at least 500 x 500 mm and ladder becomes totally accessible 3 6 13 Bottom obstruction device Bottom obstruction device interrupts descent if It encounters an obstacle It reaches the bottom platform Ascent will still be possible for ...

Page 15: ... system that can be used in case of emergency To activate it push the manual descent actuator fully upwards The electromagnetic motor brake is released The service lift descends with a controlled speed limited by means of a centrifugal brake installed between the motor shaft and the gear box 3 6 17 Overload limiter An overload limiter is built into the traction hoist In case of an overload it will...

Page 16: ...he evacuation procedure will be followed 3 6 21 Rescue pendant control 1 Rescue pendant control is only mandatory if rescue route of service lift can be somehow blocked A blocked rescue route is an event where A person is unconscious inside the service lift blocking the bottom hatch the rescuer is below service lift and the service lift is stopped halfway through a platform hole blocking rescue ro...

Page 17: ...hazardwarninglabel Bottomplatform Rescuependantcontrolemergencysign1 3 6 23 Travelling cable pulley Travelling cable is connected from power supply socket over mid tower s height platform to service lift socket and it is provided with a cable relief on each end A travelling cable pulley is suspended on the cable and is guided along the traction and safety wire ropes The travelling cable pulley str...

Page 18: ...vice activate device by pressing it down The service lift shall not move up until device is released If any faults occur during work stop working if required secure the workplace and rectify the fault Make sure that nobody is exposed to danger below the service lift for instance from falling parts g Fall arrest device Activate the fall arrest device by pulling down the red locking handle Press and...

Page 19: ...on the floor after the bottom obstruction device has stopped the lift Turn the override bottom obstruction device switch clockwise and hold Press the DOWN button until the service lift rests on the floor then release 4 6 Operation from outside the cabin automatic send configuration Transportation of people is forbidden if the operation is controlled from outside the cabin Operation by means of the...

Page 20: ...Push the lever upwards the full way The service lift moves downwards The built in mechanical overspeed limiter limits the pace of descent 3 To stop simply loosen the lever 4 After manual descent the system must be checked by an expert During manual descent if the bottom obstruction device hits an obstacle the brake release lever is mechanically disengaged so the further descent is disabled The sys...

Page 21: ...ing from the control box A6 Safety switch is triggered a EMERGENCY top limit switch was pressed b Door switch is not properly closed or is defective c Ladder access door switch is activated d A top or bottom hatch switch is triggered a Perform manual descent until the emergency top limit switch is released b Close the door and test the door switch c Close the door d Close the hatch A7 Protection s...

Page 22: ... Overload Buzzer sounds in the connection cabinet Test and possibly reduce load until buzzer stops B3 Top obstruction switch a Top obstruction switch is defective or not connected properly b Top obstruction switch is activated a Test the top obstruction switch connec tion function Replace if necessary b Move lift down until the top obstruction switch is released B4 A phase is missing Test fuses an...

Page 23: ... switch a Bottom obstruction switch is defective or not connected properly b Bottom obstruction switch is activated a Test the bottom obstruction switch connection function Replace if necessary b Move lift up until the bottom obstruction switch is released Button lamp not lit although operation is normal E A lamp is defective Have an electrician replace it Hoist goes down when up button is pressed...

Page 24: ...ttom landing floor the user starts descending by electrical power using the push down button When the cabin starts descending the user executes a hard stomp with one foot in the cabin floor The hard stomp is executed by lifting one foot so the lower leg is positioned with a knee angle of 90 degrees Then immediately after the foot is stomped in the cabin floor The user must make sure to have a soli...

Page 25: ...35 User s Manual ...

Page 26: ...I www avanti online com E info avanti online com AT00012569 Octopus L95 User s manual EN 3rd CE Edition 07 2019 Revision 1 30 07 2019 avanti online com contact ...

Reviews: