Avantco SCL1 User Manual Download Page 3

- 3 -

User Manual

Temperature Controls

•  Refrigerant LED - Compressor is on
•  Fan LED - Fan is on
•  Defrost LED - Defrost cycle is running

Functions

Adjusting the Temperature 

Refrigerators are programmed to operate between 33 and 40 degrees Fahrenheit. 
Freezers are programmed to operate between -10 and +10 degrees Fahrenheit. 
To set the temperature you would like your unit to run at, follow these instructions:
• Hold “SET” for 1 sec. The display will flash the temperature that the refrigerator is currently set to 

run at.

• Use the arrow buttons to adjust the temperature you want it to run at.
• Press “SET” again to save your settings
If the unit consistently runs 5 + degrees higher than your set temperature, service may be needed.

Note: All other control functions should be performed by a service technician.

CAUTION

Setting the temperature control to the coldest setting may cause the evaporator coil to freeze and ice 
up. This will eventually result in a warmer cabinet temperature.

NOTE

Temperature controls on the pizza prep refrigerators are located on the front of the units.  
Temperature controls on the sandwich prep tables and undercounter refrigerators and freezers are 
located on the back of the units.  

Prg

mute

Set

aux

def

Freezer Control

set

mute

Refrigerator Control

Summary of Contents for SCL1

Page 1: ...maintenance 01 2016 Refrigerated Pizza Prep Units PICL1 PICL2 PICL3 Refrigerated Sandwich Prep Units SCL1 SCL2 SCL236 SCL260 SCL3 SCLM1 SCLM2 SCLM236 SCLM260 SCLM3 Undercounter Refrigerators and Freez...

Page 2: ...tdoor use may cause decreased efficiency and damage to the unit Avoid installation in a high humidity and or dusty area Humidity could cause unit to rust and decrease efficiency of the unit Dust colle...

Page 3: ...o adjust the temperature you want it to run at Press SET again to save your settings If the unit consistently runs 5 degrees higher than your set temperature service may be needed Note All other contr...

Page 4: ...t button snowflake symbol and down arrow for approximately 3 seconds Repeat to stop the defrost cycle Defrost Systems Refrigerator coils are kept below the freezing point 32 F During compressor down t...

Page 5: ...o the compressor Unplug Cord To minimize shock and fire hazards please do not plug or unplug the cord with wet hands During maintenance and cleaning please unplug the unit Proper Grounding Required To...

Page 6: ...and motor with a soft cloth If it is necessary to wash the fan blades cover the fan motor to prevent moisture damage Cleaning The Interior of Unit When cleaning the cabinet interior use a solvent of...

Page 7: ...sket and wash with soap and water Check condition of gasket and replace if necessary Dirty condenser coil Clean the condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make...

Page 8: ...plate located on the front of the unit Next call 1 800 678 5517 Be sure to have the model number cabinet serial number and service plate number available when contacting service technicians This warra...

Reviews: