CHECKING AND ADJUSTING PRESSURE REGULATOR

The combination gas valve (includes pressure regulator) is factory set at 4" W.C. for natural gas and 10" W.C. for 

propane gas. To check the manifold pressure, do the following:
1. 

Turn thermostat “OFF” and combination gas valve knob to the “PILOT” setting.

2. 

Remove pressure tap plug from burner manifold located directly below the burners in the cabinet.

3. 

Install a fitting appropriate to connect a manometer.

4. 

Turn combination gas valve to “ON” position and thermostat to “ON.” The burners will ignite. Be certain that 

 

sufficient oil is covering the tubes.

5. 

With burners on, read manometer.

6. 

If the manometer does not read 4" W.C. for natural gas, or 10" W.C. for propane gas, adjust regulator.

7. 

Remove regulator adjustment screw cap (see diagram on page 15).

8. 

With small screwdriver rotate adjustment screw “CLOCKWISE” to increase or “COUNTERCLOCKWISE” to 

 

decrease pressure. Be sure to adjust with burners “ON.”

9. 

Turn thermostat “OFF” and set combination gas valve knob to “PILOT” position.

10. 

Remove manometer and replace pressure tap plug.

11. 

Replace adjustment screw cap.

CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT

All thermostat controls are carefully calibrated at the factory (i.e., the dial is properly set to control appliance 

temperatures accurately). Only a qualified appliance service technician should perform this adjustment.
1. 

To check appliance temperatures, use a thermocouple-type temperature test instrument or reliable 

 

thermometer. Place the thermocouple of test instrument or thermometer in the center of the frypot.

2. 

Turn the control dial to the temperature setting requiring the greatest accuracy. Allow enough time for

 

temperature to stabilize, or until several temperature 

 

readings are identical.

3. 

Recalibrate if setting and actual temperature differ  

 

by more than 10°F.

4. 

Remove dial from dial shaft “B.” Be careful that dial 

 

shaft does not rotate in either direction (which 

 

would change the dial setting).

5. 

Hold dial shaft “B” steady and with a screwdriver turn 

 

calibration screw “A” clockwise to decrease 

 

the temperature, or counterclockwise to increase  

 

the temperature.

6. 

Replace dial. Let the appliance operate until the 

 

temperature has stabilized before a final check is 

 

made to  determine whether or not the calibration  

 

has been corrected.

7. 

Once correct, seal the calibration screw with glyptol.

Summary of Contents for FF300

Page 1: ...User Manual www AvantcoEquipment com 1 Floor Fryers Models FF300 FF400 FF518 Please read and keep these instructions Indoor use only 7 16 2013 User Manual...

Page 2: ...n though not dangerous WARNING FIRE HAZARD FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Keep area around appliances...

Page 3: ...anual is for Avantco Fryers with 35 pound FF300 55 pound FF400 or 85 pound FF518 capacity frypots The capacity is described on the serial plate that is located inside the front door on the left side T...

Page 4: ...ural 4 W C 4 30 000 120 000 120 000 39 52 Propane 10 W C 4 30 000 52 FF300 Main Natural 4 W C 3 30 000 90 000 39 Propane 10 W C 3 30 000 90 000 Natural 4 W C 30 000 39 Propane 10 W C 30 000 52 Main 5...

Page 5: ...examined for damage before and during unloading The freight carrier has assumed responsibility for safe transit and delivery If damaged equipment is received either apparent or concealed a claim must...

Page 6: ...may void warranty NOTICE When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and a quick disconnect devi...

Page 7: ...pack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide the flue wrap over the flue 4 Secure it with four self tap...

Page 8: ...ir supply must also be provided Do NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect and clean the ventilation system according to the ventilation...

Page 9: ...when all units are operating simultaneously should not drop below 7 W C for natural gas or 11 W C for propane gas Fluctuations of more than 25 on natural gas or 10 on propane gas will create problems...

Page 10: ...he knob counterclockwise to the ON position Do not press down on the knob in this step 5 Do NOT turn the thermostat ON until the frypot is filled with oil or solid shortening 6 Once the frypot is fill...

Page 11: ...only the pilot burner will remain ignited Complete Shutdown Turn knob on the combination gas valve clockwise press down on the knob and continue to turn to the OFF position RELIGHTING 1 Shut off all...

Page 12: ...es will increase the life of your equipment Climatic conditions e g salt air may result in the need for more thorough and more frequent cleaning in order to keep equipment performing at optimal levels...

Page 13: ...th Dry thoroughly with a clean cloth Never use vinegar or any corrosive cleaner To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth o...

Page 14: ...n approved Avantco replacement parts are installed WARNING Adjustments and service work may be performed only by a qualified technician who is experience in and knowledgeable with the operation of com...

Page 15: ...e tap plug 11 Replace adjustment screw cap CHECKING AND ADJUSTING CALIBRATION OF THERMOSTAT All thermostat controls are carefully calibrated at the factory i e the dial is properly set to control appl...

Page 16: ...nt cap TROUBLESHOOTING NOTE Vibrations or shock caused by shaking or pounding baskets on top surface or by slamming door may cause Hi Limit Control Switch to open If this condition persists additional...

Page 17: ...User Manual www AvantcoEquipment com 17 WIRING DIAGRAM...

Page 18: ...ft side Replacement parts may be ordered either through a Entree Authorized Parts Distributor or a Entree Authorized Service Agency When ordering parts please supply the Model Number Serial Number Par...

Page 19: ...0044 1 Thermostat Fryer regulating 200 400 4 400042 1 Combination Valve Nat 4 400146 1 Combination valve LP 5 400070 1 Tubing fryer pilot 10 300031 ea Burner Fryer 11 400043 1 Safety thermopile 18 12...

Page 20: ...l 3 C200016 1 Tank 3 tube fryer excluding flue C200017 1 Tank 4 tube fryer excluding flue C400056 1 Tank 5 tube fryer excluding flue 4 400071 1 Drain extension 5 400075 1 Flue top removable 3 tube fry...

Page 21: ...User Manual www AvantcoEquipment com 21 User Manual ENTREE FRYERS Leg Parts Caster Parts 400106 400107...

Page 22: ...hanged altered modified or repaired with parts not authorized or by a nonqualified Avantco Service Technician then Avantco shall not be responsible for warranty claim 6 Adjustments such as calibration...

Page 23: ...O NEGLIGENCE SHALL NOT EXCEED THE PRICE OF THE EQUIPMENT THAT GIVES RISE TO THE CLAIM 12 If required by Avantco customer shall return to Avantco for examination any failed product or part to confirm t...

Reviews: