![Avantco 224BHAC28 User Manual Download Page 7](http://html1.mh-extra.com/html/avantco/224bhac28/224bhac28_user-manual_3025251007.webp)
- 7 -
User Manual
Trouble Shooting
The Unit is Making Noise Under the Bottom Shelf
Fan blade is broken.
Replace fan blade.
The Unit is not Cooling
Unit is turned off.
Turn unit on.
Defrost cycle is running.
End defrost cycle.
Refrigerant leaking.
Contact a licensed service technician.
High Cabinet Temperature Caused by Weak Air Flow
Evaporator coil is frosted over.
Run a manual defrost cycle.
Fan is damaged.
Replace the fan.
The set point on the controller is too high.
Set the controller to a lower temperature. The set
temperature is the lowest temperature the refrigerator
will reach.
Air flow is blocked by product.
Rearrange or remove product to allow for complete air
flow.
High Cabinet Temperature with Normal Air Flow
Refrigerant leaking.
Contact a licensed service technician.
The set point on the controller is too high.
Set the controller to a lower temperature. The set
temperature is the lowest temperature the refrigerator
will reach.
Expansion valve failed.
Contact a licensed service technician.
The air curtain is being disturbed by strong air flow.
Make sure the cabinet is located away from doors,
windows, and other air vents.
High ambient temperature or humidity.
This refrigerator is designed to perform in
temperature-controlled environment up to 75
°
F and
65% relative humidity.
Cabinet Temperature is Fluctuating
Condenser coil is dirty.
Clean the condensor coil.
Unit has improper air flow.
Make sure the unit has at least 6" of clearance on the
back and that the front vents are not obstructed.
Expansion valve blocked or failed.
Contact a licensed service technician.
Temperature controller failed.
Contact a licensed service technician.