Troubleshooting

Compressor Not Running

 

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit breaker.

Power cord unplugged.

Plug in power cord.

Thermostat set too high.

Set thermostat to lower temperature.

Cabinet in defrost cycle.

Wait for defrost cycle to finish.

Condensing Units Run For Long Periods of Time.

Excessive amount of warm product placed in cabinet.

Allow adequate time for product to cool down.

Prolonged drawer opening or drawer ajar.

Ensure drawers are closed when not in use. Avoid 
opening drawers for long periods of time.

Dirty condenser coil.

Clean the condenser coil.

Cabinet Temperature is too Warm.

Thermostat set too warm.

Set thermostat to lower temperature.

Excessive amount of warm product placed in cabinet.

Allow adequate time for product to cool down.

Fuse blown or circuit breaker tripped.

Replace fuse or reset circuit breaker.

Dirty condenser coil.

Clean the condenser coil.

Cabinet has Excessive Condensation.

Relative humidity is too high.

Relocate cabinet away from doors and windows to an 
air conditioned area.

Night covers have condensation.

Some condensation is normal.

Summary of Contents for 178CPSS47HC

Page 1: ...e Cream Dipping Cabinets 1 User Manual Please read the manual thoroughly prior to equipment set up operation and maintenance 178CPW47HC 178CPSS47HC 178CPW68HC 178CPSS68HC 178CPW88HC 178CPSS88HC 10 201...

Page 2: ...IGORIG NE EST INFLAMMABLE CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION D...

Page 3: ...or use may cause decreased efficiency and damage to the unit Avoid installation in a high humidity and or dusty area Humidity could cause unit to rust and decrease efficiency of the unit Dust collecte...

Page 4: ...will run at Your unit will not run constantly at this setting To change it follow these instructions Digital Control Units Hold SET for 1 sec The display will flash the current minimum temperature Us...

Page 5: ...of the cabinet After defrosting clean the wall with a dry cloth and then turn the power back on To run a manual defrost press the defrost button snoflakes symbol and down arrow for approximately 3 sec...

Page 6: ...ast 10 minutes before plugging it back in Failure to do so could cause damage to the compressor Unplug Cord To minimize shock and fire hazards please do not plug or unplug the cord with wet hands Duri...

Page 7: ...from any kitchen equipment retailer Brush the condenser fins from top to bottom not side to side After cleaning straighten any bent condenser fins with a fin comb Cleaning The Fan Blades and Motor If...

Page 8: ...or drawer ajar Ensure drawers are closed when not in use Avoid opening drawers for long periods of time Dirty condenser coil Clean the condenser coil Cabinet Temperature is too Warm Thermostat set too...

Reviews: