background image

- 6 -

User Manual

Prg

mute

Set

aux

def

Freezer Control

set

mute

Refrigerator Control

Running a Manual Defrost Cycle

This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you 
would like to run a manual defrost cycle at any time, please follow the steps below:

Freezers: Press the defrost button (“def” and down arrow) for approximately 5 seconds. Repeat to 

stop the defrost cycle. 

Refrigerators: Press the defrost button (snowflake symbol and down arrow) for approximately 3 
seconds. Repeat to stop the defrost cycle. 

Defrost System

Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit).  During compressor 
down-time, the evaporator fan continues to circulate air through the evaporator coil.  This air 
circulation raises the coil temperature above the freezing point, melting any accumulated frost.   
Run-off water is drained into the evaporator pan and evaporated.  Freezer coils are defrosted 
electrically.  Automatic defrost timers automatically initiate at pre-set intervals and for a pre-
determined duration.

Operation/Maintenance

 

NOTE: We strongly recommend that any servicing be performed by an authorized service technician.

Loading Product

•  Do not block the air duct / fan at the top of the unit.  Maintain a minimum of 4” of clearance 

between products and the fan at all times.

• Ensure all shelves are sitting level and properly secured before loading products.
• Do not store flammable and explosive gas or liquids inside the unit.

Summary of Contents for 178A12RHC

Page 1: ...Manual Refrigerator models 178A12RHC 178A19RHC 178A23RHC 178A23RGHC 178A35RHC 178A49RHC 178A49RGHC Freezer models 178A12FHC 178A19FHC 178A23FHC 178A35FHC 178A49FHC Please read the manual thoroughly pr...

Page 2: ...IGORIG NE EST INFLAMMABLE CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION D...

Page 3: ...orized service technician for servicing repair Do not hang on doors or stand inside the unit Please read through this manual in its entirety Field Convertible Doors The Avantco A 19R A 19F A 23R and A...

Page 4: ...nd the top panel Cabinet Location Guides Install the unit on a strong and leveled surface If the surface is uneven the unit may be noisy The unit may malfunction if the surface is uneven Install the u...

Page 5: ...atures for food safety and should require no adjustments Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freeze...

Page 6: ...uring compressor down time the evaporator fan continues to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated f...

Page 7: ...es cover the fan motor to prevent moisture damage Cleaning the Interior of Unit When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive...

Page 8: ...cked Re arrange products to allow for proper air flow Make sure there is at least four inches of clearance from the fan Low refrigerant levels Contact a service technician to check refrigerant levels...

Reviews: