Installation Instructions

1. The gas supply line must be of adequate size to ensure maximum efficiency of the unit.

2.  The installation must conform with local codes, or in the absence of local codes, with the National Fuel 

Gas Code, ANSI Z223. 1/NFPA 54 including:

 

a.  The appliance and it’s individual shut-off valve must be disconnected from the gas supply piping 

system during any pressure testing of that system at test pressure in excess of ½ psig (3.5 kPa).

 

b.  The appliance must be isolated from the gas supply piping system by closing it’s individual manual 

shutoff valve during any pressure testing of the gas supply piping system at test pressure equal or 
less than ½ psig (3.5 kPa).

3. Local regulations governing gas appliance installations must be complied.

4. Equipment should be in an area with adequate ventilation.

5.  Minimum spacing of 6” to combustible construction is required along back and side walls. Clearance for 

noncombustible construction are the same as combustible clearances. For use only on noncombustible 
surfaces.

6.  Materials such as wood, compressed paper and plant fibers that will ignite and burn, must not be exposed 

near the unit. Local safety codes should be complied with in respect to fire hazard avoidance.

7.  Use of the supplied pressure regulator is mandatory. Note that the use of 2 regulators may cause 

insufficient gas flow. Consult with installer but always comply with above codes. 

8.  Keep the appliance area free and clear from combustible materials, gasoline and other flammable vapors 

and liquids. 

9.  Locate the appliance in a well ventilated area. Do not block or cover the opening between the shroud and 

pot. Do not obstruct flow of combustion and ventilation air.  

10. The unit must be installed with adequate clearance for servicing and proper operation. 

11.  If the unit is connected to a flexible gas line, the installation must be made with a connector that complies 

with the Standard Connectors for Movable Gas Appliances, ANSIZ21.6, and a Quick Disconnect device 
that complies with the standard for Quick Disconnect Devices for Use with Gas Fuel ANSIZ21.41, 
and adequate means must be provided to limit the movement of the appliance without depending on 
connector and the Quick Disconnect Device or it’s associated piping to limit movement of the appliance. 

12. Before connecting gas check that gas valve is turned OFF (gas valve handle in the vertical position).

13.  Check for leaks using soapy water or other suitable leak detector. Rinse off the soapy water after testing. 

Do not use open flame for testing. 

Summary of Contents for 177GRCLP

Page 1: ... not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance Instructions thoroughly before installing or servicing this equipment 5010781 Conforms to ANSI STD Z83 11 2016 Intertek ...

Page 2: ...ctions for future reference Index Safety Precautions 3 Specifications 4 Parts List 4 Safe Usage 5 Placement 5 Installation Instructions 6 7 Before Use 8 Notice 8 9 Instructions 9 10 11 Cleaning Method 12 Maintenance Instructions 12 Troubleshooting 13 Warranty 14 ...

Page 3: ...not block the steam outlet on the cookers lid or exhaust outlet 4 Use a qualified gas pipeline 5 Please do not use gas pipe made of vinyl or rubber 6 When cooker is not in use make sure gas intake valve is closed E Other Special Cases In case you notice any unusual circumstances such as gas combustion are different now strange smell strange noise ect please remain calm immediately turn off gas int...

Page 4: ...er 0 4MM Model No GRCNAT Power Rating 14 000 BTU Capacity 110 cups 55 cups raw Weight 33 6 lb Dimensions 201 4 D x 171 8 H Orifice Size Drill For Main Burner 1 8MM Orifice Size for Permanent Pilot 0 3MM Orifice Size for Ignition Burner 0 6MM Parts List NO PART NAME 1 Water Pan 2 Flame Failure Device 3 Burner 4 Connector 5 Gas Switch 6 Cooking Knob 7 Warming Knob 8 Ignition Knob 9 Bottom Base 10 Wa...

Page 5: ...e NOTE Current national gas types 1 Liquid Propane Gas Y 2 Natural Gas T 3 Manufactured Gas R Placement Keep away from combustible substances Place in area with good ventilation The side and back clearance must be more than 5 9 in The above clearance must be more than 19 68 in Place on a flat surface Avoid placing in humid location to extend life of the unit ...

Page 6: ...it Local safety codes should be complied with in respect to fire hazard avoidance 7 Use of the supplied pressure regulator is mandatory Note that the use of 2 regulators may cause insufficient gas flow Consult with installer but always comply with above codes 8 Keep the appliance area free and clear from combustible materials gasoline and other flammable vapors and liquids 9 Locate the appliance i...

Page 7: ...IGNITE button also engages the WARMING button and exposes it It will stay down until pushed up to extinguish the pilot If the pilot has not lit repeat until the pilot lights 5 If the pilot fails to remain lit refer to Trouble Shooting on page 13 6 Replace the pot wind shield and base cover in their proper order With the pilot lit push the THEN COOK button down to its position without water in the ...

Page 8: ... the hose regularly and change immediately if it becomes compromised Do not place the hose underneath the cooker Notice Failure will occur if the water pan wind shield and inner pot are placed improperly Confirm the following before using for best performance 1 Water pan is placed correctly underneath the bottom Improper placement would cause unsuccessful ignition or flame out NOTE Reversed placem...

Page 9: ...burner dry To avoid incomplete combustion do not cover the top of the rice cooker Stay in proximity when the rice cooker is on This is to avoid gas leakage caused by wind blow off Clean the water in the inner pot to avoid burning It is normal for the color of the aluminum inner pot to change This might be due to water quality insufficient cooking water consecutive cooking or remained rice pulp It ...

Page 10: ... down COOK BUTTON COOK BUTTON goes up automatically when cooking is finished 6 The cooker keeps warm after COOK BUTTON resumes OFF position 7 Pull WARM BUTTON upwards when warming function is not needed 8 Turn gas valve to OFF position If ignition does not occur in 5 seconds turn the burner control s off wait 5 minutes and repeat the lighting procedure The WARM BUTTON is not visible when the unit ...

Page 11: ...t open the lid after the flame is out Wait about 15 to 20 minutes to avoid possible injury NOTE The recommended time for warming rice is one hour Pull the WARM button upwards when warming is not needed Air Adjustment 1 Place the air conditioning plate at the correct position for effective combustion NOTE If combustion is unsuccessful adjust the air conditioning plate until the flame is visible How...

Page 12: ...of the Lid Clean with soap and water Cleaning of Burner Black burner orifice or inset net will cause incomplete combustion In order to have effective combustion clean the burner regularly Please use needle to clean the burner hole to make the flame normal NOTE Do not use water to clean the burner Maintenance Instructions 1 Contact factory the factory representative or a local service company to pe...

Page 13: ...r pan 1 Thermal expansion device replacement 2 Assemble the parts test with the empty pot for 2 3 minutes 1 Use exclusive HVR only 2 Uneven display will cause early switch off watery rice or burned rice Soak the rice for 30 minutes for better performance Wait for 15 20 minutes after the COOK is pulled up to dry moisture in the cooker Water may vary depending on rice texture a e g Water may be redu...

Page 14: ...no event be liable for direct indirect or consequential damages in connection with Avantco commercial products This warranty is not effective if damage occurs because of accident carelessness improper installation lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and operating instructions Work performed by unaut...

Reviews: