Troubleshoot
Avant 755i 760i
138
Problem
Possible cause
Remedy
DPF regeneration does not
start
DPF regeneration is inhibited
manually
Check DPF settings on display
Engine coolant temperature is
low
Engine load might not be high enough to keep engine coolant
temperature above required minimum for DPF. Increase engine
load.
Engine coolant may be too low for DPF regeneration due to
faulty thermostat. Check operation of thermostat, contact
service.
Engine overheats
Clogged radiator
Clean radiator and fan from engine side.
Dirt around engine
Clean engine and its surroundings carefully
Coolant level low
Add coolant.
Leaking cooling system
Check coolant pressure reservoir cap for tightness. Check
cooling system and all hoses and connections.
Hydraulic attachment does
not work when the auxiliary
hydraulics control lever is
moved
Attachment hoses are not
coupled or the multi connector
is not fully locked.
Make sure that the multi connector is properly connected.
Faulty or damaged quick
couplers (will restrict or stop oil
flow)
Replace quick couplers in multi connector.
Operator not seated on driver's
seat
Operator must sit on driver's seat to activate auxiliary
hydraulics. Also, other operating mode can be selected to
operate certain attachments from another control position, see
page 56.
Fault in attachment
Check with another attachment, if possible.
Attachment hoses will not go
into the extra front or rear
quick couplers of the loader
There is back pressure in the
auxiliary hydraulics line.
Release the pressure by moving the extra auxiliary hydraulics
control lever in both directions.
Hydraulic system overheats
Hydraulic oil level low
Check and refill, see page 117.
Clogged oil cooler
Clean cooler and fan
Fan faulty
Check and clean, repair if necessary
Hydraulic oil flow restricted
Make sure auxiliary hydraulics valve is completely opened
when using high flow attachments. Adjust lever locking plate if
necessary.
Hydraulic system overloaded
Use attachment at lower engine rpm, use with 1-pump setting,
check attachment for faults.
The loader does not move
even after the parking brake
has been released.
PTO switch is in position ON
Return PTO switch to position OFF to activate drive pedals
Seat belt is unfastened
If loader is equipped with mandatory seat belt monitoring, seat
belt must be fastened. Unfasten the seat belt, and fasten it
again.
Bad connection on the wiring of
the parking brake switch, blown
fuse, or faulty switch
Check wires, fuse, and switch, repair if necessary. Contact
service.
Low hydraulic charge pressure
Contact service for pressure check.
Faulty solenoid valve
Check and replace if possible. Contact service